Operating instructions
Operating advanced function _33
ENGLISH
•Code40:User’soptionsforheatingdevicesincludinginternalbackupheaterandexternalboiler
401:Space/DHWheatingpriorityandcontrolvariables
402:Backup/Boosterheaterpriorityandcontrolvariables
403:Additionalbackupboileroperatingvariables
•Code50:User’soptionsforextrafunctions
501:Newtargettemperaturesofeachmodeby“Outgoing”hotkeyofremotecontroller
5021:Temperaturedifferencebetweenbefore&aftervaluesin“Economic”DHWmode
504:PowerPeakcontrolforSmartGrid
FieldSettingValue
Main Menu &
Code
Sub Menu Function Description Sub Code Default Min Max Step Unit
Heating Code
40
Heat Pump Heating/DHW Priority
11 0(DHW) 0 1(Heating) - -
Outdoor Temp for Priority
12 0 -15 20 1 ˚C
Heating Off
13 35 14 35 1 ˚C
Overshoot
14 2 1 4 1 ˚C
Backup Heater Application
21 1(Off) 0 1(On) - -
BUH/BSH Priority
22 0(Both) 0 2(BSH) 1 -
Cold weather compensation
23 1(On) 0(Off) 1 - -
Threshold Temp
24 0 -15 35 1 ˚C
Defrost Backup Temp.
25 15 10 55 5 ˚C
Backup Boiler Application
31 0(No) 0 1(Yes) - -
Boiler Priority
32 0(Off) 0 1(On) - -
Threshold Temp
33 -15 -20 5 1 ˚C
Others Code
50
Outing Water Out Temp for Cooling
11 25 5 25 1 ˚C
Room Temp for Cooling
12 30 18 30 1 ˚C
Water Out Temp for Heating
13 15 15 55 1 ˚C
Room Temp for Heating
14 16 16 30 1 ˚C
Auto Cooling WL1 Temp
15 25 5 25 1 ˚C
Auto Cooling WL2 Temp
16 25 5 25 1 ˚C
Auto Heating WL1 Temp
17 15 15 55 1 ˚C
Auto Heating WL2 Temp
18 15 15 55 1 ˚C
Target Tank Temp
19 30 30 70 1 ˚C
DHW Saving Mode Temp Difference
21 5 0 40 1 ˚C
Power Peak
Control
Application
41 0(No) 0 1(Yes) - -
Select forced off parts
42 0 0 2 - -
Using input voltage
43 1(High) 0(Low) 1 - -
•Code5042
[D-00] Compressor Backupheater Boosterheater
0(Default) Forced off Forced off Forced off
1 Forced off Forced off Permitted
2 Permitted Forced off Forced off










