QUESTIONS OR COMMENTS COUNTRY CALL OR VISIT US ONLINE AT INDONESIA 021-56997777 08001128888 www.samsung.com/id/support PHILIPPINES 1-800-10-7267864 [PLDT] 1-800-8-7267864 [Globe landline and Mobile] 02-4222111 [Other landline] www.samsung.com/ph/support THAILAND 0-2689-3232 1800-29-3232 www.samsung.com/th/support VIETNAM 1 800 588 889 www.samsung.com/vn/support Importir: PT. Samsung Electronics Indonesia Jl.
AF28FVSDA Series AF28FVZDA Series Air Conditioner user & installation manual imagine the possibilities Thank you for purchasing this Samsung product. EN TH IN VI DB68-03955A-02 S-east_MEMORY_IBIM_03955A-02_co_EN.
Features of your new air conditioner Samsung Air Solution! Cool, Clean and refreshing feeling at once Cool Air : Your air conditioner uses air flow direction control which provide direct air flow in hot days and indirect air flow when you are cooled down. Refreshing Air : Auto mode will provide refreshing air by selecting the operation mode automatically from Cool, Dry, Purity depending on the indoor air environment.
Contents USING PARTS ENGLISH Safety precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Checking before use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
USING PARTS Safety precautions Before using your new air conditioner, please read this manual thoroughly to ensure that you know how to safely and efficiently operate the extensive features and functions of your new appliance. If you have any questions, call your nearest contact center or find help and information online at www.samsung.com. Important safety symbols and precautions: WARNING Hazards or unsafe practices that may result in severe personal injury or death.
ENGLISH Do not install this appliance near a heater, inflammable material. Do not install this appliance in a humid, oily or dusty location, in a location exposed to direct sunlight and water (rain drops). Do not install this appliance in a location where gas may leak. ff This may result in electric shock or fire. Never install the outdoor unit in a location such as on a high external wall where it could fall. ff If the outdoor unit falls, it may result in injury, death or property damage.
Safety precautions FOR POWER SUPPLY WARNING When the circuit breaker is damaged, contact your nearest service center. Do not pull or excessively bend the power line. Do not twist or tie the power line. Do not hook the power line over a metal object, place a heavy object on the power line, insert the power line between objects, or push the power line into the space behind the appliance. ff This may result in electric shock or fire.
ENGLISH Do not operate the appliance with wet hands. ff This may result in electric shock. Do not strike or pull the air conditioner with excessive force. ff This may result in fire, injury, or problems with the product. ff Importantly, if the support bracket is excessively impacted, it may become damaged. Do not place an object near the outdoor unit that allows children to climb onto the machine. ff This may result in children seriously injuring themselves.
Safety precautions FOR USING WARNING Do not insert your fingers or foreign substances into the air inlet/outlet of the air conditioner. ff Take special care that children do not injure themselves by inserting their fingers into the product. Do not use this air conditioner for long periods of time in badly ventilated locations or near infirm people. ff Since this may be dangerous due to a lack of oxygen, open a window at least once an hour.
FOR CLEANING ENGLISH Do not spray volatile material such as insecticide onto the surface of the appliance. ff As well as being harmful to humans, it may also result in electric shock, fire or problems with the product. Do not drink the water from the air conditioner. ff The water may be harmful to humans. Do not apply a strong impact to the remote controller and do not disassemble the remote controller. Do not touch the pipes connected with the product. ff This may result in burns or injury.
Safety precautions FOR CLEANING CAUTION Take care when cleaning the surface of the heat exchanger of the outdoor unit since it has sharp edges. ff To avoid cutting your fingers, wear thick cotton gloves when cleaning it. Do not clean the inside of the air conditioner by yourself. ff For cleaning inside the appliance, contact your nearest service center. ff When cleaning the internal filter, refer to the descriptions in the ‘Cleaning the air conditioner’ section.
Checking before use Using indoor unit ENGLISH Make sure that curtain does not block the air inlet. ff It may decrease cooling performance by blocking air circulation. In Cool mode, set the appropriate desired temperature. ff If the desired temperature is too low, it may be harmful for human body and power consumption will also increase. Set the desired temperature about 5°C lower than the outdoor temperature. When cooling the room, use air conditioner and fan together to save energy.
Checking before use Auxiliary power switch Turn on the auxiliary power switch which is installed separately. (Only applicable for outdoor unit with separate power supply) NOTE Auxiliary power switch (NFB, ELB, etc.) • Auxiliary power switch is not included in the package. Purchase and install it separately. • Auxiliary power switch is a device for preventing over-current or short circuit. Install it separately near the indoor unit and turn it off when cleaning or when you don’t use it for long time.
Checking the name of the parts Your air conditioner may slightly look different from illustration depending on the model.
Checking the name of the parts Display Fan speed Mute Virus doctor Timer Cleaning good'sleep mode Temperature Outdoor unit operation Air conditioner operation mode Current operation mode is displayed. Smart sensor operation Buttons on control panel On/Off button Temperature control button Increase or decrease the temperature by 1 ˚C Individual control button ❋❋ The number of air outlets is different depending on the models. 14 S-east_MEMORY_IBIM_EN_03955A-02_EN.
Operation with control panel 1. Press the Power button to operate the air conditioner. ffThe air outlets will open in order with melody sound and the air conditioner will operate with auto mode. Press the Power button one more time. ENGLISH Stop 2. Press the [ ], [ ] buttons to adjust the desired temperature. ffWhen pressing the button first, the mode of air conditioner will change to cool mode.
Checking the remote controller Function may be different depending on the model. ffPoint the remote controller towards the remote control receiver of the unit. ff When the button is pressed, you will hear ringing or beep sound and Transmit indicator ( controller display.
Remote controller display Operation mode indicator Transmit indicator Low battery indicator ENGLISH Set temperature/ Time indicator Fan speed indicator Auto Low Medium High On/Off Time indicator Air flow direction indicator ❋❋ Heat mode will be displayed on the remote controller and reception sound will be ringing but the air conditioner will not operate the heat mode.
Basic operation Basic operation is an operation mode that can be selected by pressing the Mode button. Auto In Auto mode, the air conditioner will automatically set the operation mode in Cool/Dry/Fan mode to provide refreshing air throughout your indoor area. ffIn Auto mode, the air conditioner will automatically set the operation mode depending on the indoor surrounding.
Press the button to turn on the air conditioner. Family mode Solo mode ENGLISH Press the button to set Solo/Family mode. • Solo : Select this function if you are alone in the room or want to save your electricity bill. • Family : Select this function if there are lots of people in the room or require powerful cooling. Remarks The middle air outlet will be closed when the air conditioner reaches the desired temperature in solo mode.
Turbo operation Turbo function will be helpful to cool your room quickly and effectively. Press the button on the remote controller in the Cool mode. ffTurbo indicator appears on the remote controller display and the air conditioner will operate in Turbo function for 30 minutes. ff Cancel Press the Turbo, Mode, Quiet, Smart Sensor or good`sleep button. WPS Wi-Fi NOTE • Turbo function is only available in the Cool mode.
good'sleep operation For a comfortable sleep, the air conditioner will operate in Fall asleep Sound sleep Wake up from good’ sleep mode. When the air conditioner is on and in cool mode. Lighting Wi-Fi ENGLISH WPS 1. Press the good'sleep button on the remote controller to select the good'sleep mode. ffgood'sleep indicator appears and Off timer indicator starts blinking on the remote controller display. 2. Press the good'sleep button to set the time.
good'sleep operation Temperature and fan speed changes in good'sleep mode 1. Fall asleep mode : Provides you with a comfortable environment for a good sleep by rapidly cooling your room and releasing a breeze that induces sleep. 2. Sound sleep mode : The sound sleep mode adjust temperature and air flow in waves to maintain healthy skin temperature while it aids deep sleep. According to the change of good’ sleep operation hours, the sound sleep hour can be longer or shorter. 3.
Setting the On/Off timer You can set the air conditioner to turn on/off automatically at desired time. Setting On timer while the air conditioner is off / Off timer while the air conditioner is on. ENGLISH Lighting 1. Press the On timer or Off timer button. ffOn/Off timer indicator will blink on the remote controller display. 2. Press the On timer or Off timer button repeatedly to set the time. ffYou can set the time in half hourly units from 30 minute ~ 3 hours and hourly units from 3 hour ~ 24 hours.
Setting the On/Off timer Combining On Timer and Off Timer If the air conditioner is Off Preset time on On timer is shorter than Off timer Ex) On timer : 3 hours, Off timer : 5 hours -- The air conditioner will turn on after 3 hours from the moment you have set the timer. Your air conditioner will remain on for 2 hours and then turn off automatically.
Smart sensor operation In Cool mode, camera on the top of the indoor unit will detect the movement within the indoor and when there is no movement for certain time, air conditioner will adjust the indoor temperature or turn off power automatically. Press the button during Cool mode. ❋❋ Applicable to AF✴✴FVSD✴✴✴ only Wi-Fi ENGLISH WPS ff icon appears on the remote controller display and the icon appears on the indoor unit display.
Quiet operation This function can reduce the noise generated during air conditioner operation. Press the button to select Quiet function. ff icon will appear on the remote controller display. Cancel Press the Quiet, Mode or Fan , button once again. Lighting You can adjust the desired temperature by 1 °C within the range of 18 °C~30 °C. Since the fan speed is fixed as cancel the Quiet operation. (Auto), pressing the Fan , button will You can set the air flow direction.
Cleaning the air conditioner CAUTION • Make sure to turn off the circuit breaker when cleaning the air conditioner. ENGLISH Cleaning the indoor unit ffWipe the surface of the unit with a slightly wet or dry cloth when needed. ffBrush away the dust on the narrow gap of air conditioner. NOTE CAUTION • Since the panel of the product can be scratched easily, use the exclusive cleaning cloth (micro fiber) for cleaning.
Cleaning the air conditioner Cleaning the Full HD filter Full HD filter filters the big dust of incoming air. Pull out the Full HD filter in the arrow direction. ffBefore pulling out the lower Full HD filter, take out the Zero filter first. Remove dust with a vacuum cleaner or running water. ffWhen the dust is serious, clean the filter with warm water which contains a neutral detergent. However, when rubbing out the filter with a brush, the Full HD filter may be damaged.
Cleaning the Zero filter Zero filter traps small dust particles within the air. It is washable and it can be used semi-permanently. Soak the filter in the water and shake it up and down for few times. ffDo not disassemble the Zero filter when cleaning it. ffIf the accumulated dust is heavy, soak the filter in water mixed with detergent and shake it in water for 30 minutes until it is cleaned. Push the Zero filter in the direction of the arrow and make sure it is fixed in correct position.
Troubleshooting Refer to the following chart if the air conditioner operates abnormally. This may save time and unnecessary expenses. PROBLEM The air conditioner does not work at all. Front panel remains open. SOLUTION • Check power status and then operate the air conditioner again. • Switch on the circuit breaker and then operate the air conditioner again. • Check if the air conditioner is turned off by Off timer or Smart sensor. Operate the air conditioner again by pressing the Power button.
PROBLEM Timer function does not work. The air conditioner is not turned off. Odors permeate in the room during operation. Error is indicated ENGLISH Remote controller is not working. SOLUTION • Check if your batteries are depleted. • Make sure nothing is blocking your remote controller sensor. • Check whether there are strong lighting apparatus near the air conditioner. Strong light which comes from fluorescent bulbs or neon signs may interrupt the electric waves.
Troubleshooting PROBLEM SOLUTION • Depending on the status of the air conditioner usage, noise can be heard when refrigerant flow movement changes. It is normal. Noise is generated • Crackling sound may occur during the operation of the air conditioner, push the Zero filter to the end. • Water may be generated because of the temperature difference. It is Water is dropping from normal. the outdoor • When the humidity difference of air outlet is big, water drop may unit piping be formed and dripping.
Open Source Announcement The software included in this product contains open source software. You may obtain the complete corresponding source code for a period of three years after the last shipment of this product by sending an email to mailto:oss.request@samsung.com. ENGLISH It is also possible to obtain the complete corresponding source code in a physical medium such as a CD-ROM; a minimal charge will be required. The following URL http://opensource.samsung.
Installation parts Safety precautions Carefully read the content of this manual before installing the air conditioner and store the manual in a safe place in order to be able to use it as reference after installation. WARNING Hazards or unsafe practices that may result in severe personal injury or death. CAUTION Hazards or unsafe practices that may result in minor personal injury or property damage. WARNING ffInstallation must be carried out by a qualified installer.
WARNING ENGLISH ffDo not assemble the power cord on your own, use two cables together to extend the cable length or tangle the cable. -- Bad connection, isolation and over voltage may cause fire or electric shock. ffMake sure to turn off the main power when setting up the indoor unit electrical circuit or power cords. -- There is a risk of electric shock. ffInstall a ground leakage breaker depending on the installation place. -- If not, it may cause electric shock.
Required tools General tools ① Vacuum pump ② Torque wrench ③ Pipe cutter ④ Reamer ⑤ Pipe bender ⑥ Spirit level ⑦ Screw driver ⑧ Spanner ⑨ Drill ⑩ L wrench ⑪ Measuring tape Tools for test operations ① Thermometer ② Resistance meter ③ Electroscope 36 S-east_MEMORY_IBIM_EN_03955A-02_EN.
Choosing the installation location Indoor unit ENGLISH ffInstall the unit at a place close to the wall facing the outside as it is necessary to perform piing connection with the outdoor unit. -- It is effective to install the unit at the place where air flow is not blocked and the cool air can be distributed throughout the room. ffInstall the unit at a place where there is no obstacle against the wind around the air intake and air outlet. ffAvoid a place near the door which is frequently used by people.
Indoor/outdoor unit installation diagram Installation space for floor type indoor unit ffTo minimize the waste of space due to installation, install the indoor unit as shown in below figure. -- Top view ❋❋ After completing the installation, remove the protection vinyl. (Be careful of static electricity). ❋❋ After completing the installation, remove the protective filament film on the product. 50 cm or more CAUTION • Make sure that there are no obstacles (such as curtains etc.
Fixing outdoor unit Follow below method to firmly fix the outdoor unit. ffUsing rubber leg -- Put the rubber leg to the outdoor unit leg. (Refer to illustration on the right.) 338 mm ENGLISH ffUsing anchor bolt Anchor bolt fixing dimension 660 mm -- On a flat, rigid ground, use 4 anchor bolt (M10) to fix the unit. (Anchor bolt should be purchased separately.) -- Select the anchor bolt that is long enough to securely fix the outdoor unit.
Accessories Indoor unit accessories Remote controller Fixing bracket for indoor unit Batteries M4 x 16 screws User & installation manual Cleaning cloth (micro fiber) Remote controller holder Outdoor unit accessories Main power cable Indoor/outdoor unit communication cable Indoor/Outdoor unit power cable Drain connection hose Connection pipe & Insulation (Φ6.35 mm) Connection pipe & Insulation (Φ15.
Drilling a hole and fixing the indoor unit ffDrill a hole with diameter of 60~65 mm towards the outside. ffIf the indoor unit is installed on unstable ground, it may be shaken by an external force or children, and eventually get knocked down. To prevent these accidents, you must fix the top or back of the indoor unit tightly with fixing brackets. 200 mm ø60~65 mm ENGLISH 150 mm or less Connecting pipes WARNING • When installing, make sure there is no leakage.
Connecting pipes 2. Bend the connection pipe to an appropriate length using a bender depending upon the installation place. 3. Perform pipe bending process. -- Perform bending of the pipe using the pipe bender which has a specified bending radius. -- Be sure to take full care to perform bending of the pipe successfully at one time. Bending and unbending the pipe more than twice makes the bending work increasingly difficult. 4. Connect the high pressure pipe (ø6.35 mm) and low pressure pipe (ø15.
ffTightening of connection parts Alight the pipes to be connected and tighten the flare nuts with your hands first and then with a torque wrench, tighten it in a direction shown in below illustration. -- You can avoid of gas leakage by applying refrigerant oil on the flare connection part. Pipe Flare connection part ENGLISH Monkey spanner Torque wrench Flare nut Diameter(D) ø6.35 mm ø9.52 mm ø12.70 mm ø15.88 mm ø19.
Connecting drain hose 1. Slightly hit the hole, for drain hose, with your hands or hammer. 2. Insulate the drain hose with drain insulation tube and fix it with tape. 3. Direct the drain hose downward to establish natural draining. -- Make sure to check for proper drainage after connection CAUTION • Fix the drain hose tightly to prevent any water leakage. • Do not use the extended drain hose. -- Since water may leak from the connection part, make sure that you do not extend the drain hose.
Electrical work CAUTION • The electrical work should be performed by a specialist qualified for the work. • Avoid using multi-concent but use rate power supply for air conditioner. (Use separate power cable for outdoor unit.) Type Indoor unit Indoor power (Indoor/outdoor unit power cable) Outdoor unit Outdoor power (Earth leakage circuit breaker) Power ENGLISH Wiring standard ffAlways make sure that the power supply is compliant with current safety standards.
Electrical work Safety information on outdoor unit power supply ffPower supply cords of parts of appliances for outdoor use shall not be lighter than polychloroprene sheathed flexible cord. (Code designation IEC:60245 IEC 66 / CENELEC: H07RN-F ) -- Rated voltage: 450/750V, H07RN-F (60245 IEC 66) -- Use cable over 2.5 mm2 (Distance : 15 m or less) Type of outdoor unit power supply ffComply with tightening torque to make sure that the screws do not get loose. Screw M4 Torque kgf•cm N•m 12~18 1.2~1.
How to connect your extended power cables ffItems to prepare Tools Crimping plier Connection sleeve (mm) Insulation tape Contraction tube (mm) Spec MH-14 20 x Ø6.5(H x OD) Width 19 mm 70 x Ø8.0(L x OD) 1. As shown in the figure, peel off the shields from the rubber/wire of the power Power cable(provided by us) cable. -- Peel off 20 mm of the wire shields of the tube installed already. 20 20 (Unit: mm) ENGLISH Shape 20 60 120 180 20 Power cable (provided by us) 2.
Electrical work 4. Wrap it with the insulation tape twice and position your contraction tube in the middle of the insulation tape. ffMethod 1 ffMethod 2 Insulation tape 40 mm Insulation tape 35 mm 5. Apply heat to the contraction tube to contract it. Contraction tube 6. After tube contraction work is completed, wrap it with the insulation tape to finish. Insulation tape CAUTION • In case of extending the electric wire, please DO NOT use a round-shaped pressing socket.
Vacuum pump Vacuuming pipe ENGLISH 1. Completely connect the indoor/outdoor unit pipes. 2. Connect the manifold gauge to the service valve port of the low pressure side on the outdoor unit. 3. Execute vacuum pump for over 30 minutes. -- If the pipe extension is larger, time of the vacuum pump should also get longer. 4. After degree of vacuum has been established, open the service valve ➀~➁ as shown in the illustration.
Performing leak test ffUse leak tester or soapsuds on the pipe connection part after performing vacuum pump. Check for leakage Test part for indoor unit Check for leakage Test part for outdoor unit ffBefore inspecting the leakage, use a torque wrench to close the cap for the service valve.(Comply with a tightening torque for each size of the diameter, and tighten the cap firmly to prevent any leakage.
Installing the earth wire Earthing must be done by the installation specialist for your safety. ffConnect grounding electrode and the air conditioner. 1. Connect the manifold gauge in the low pressure side (gas) and press Set/Cancel, Mode, Temp + button simultaneously for 5 seconds to enter the refrigerant charging mode. When the outdoor unit operates, charge the refrigerant. 2. Charge the refrigerant depending on the pipe length.
Check and test operation 1. Supply power to the air conditioner. 2. Turn on the air conditioner. 3. While pressing and holding the Set/Cancel button on the remote controller, press the Power button for 3 seconds to display the temperature of indoor heat exchanger. -- Write down the displayed temperature. 4. Press the Turbo button on the remote controller to operate in turbo mode for 10 minutes. 5. Check if the indoor unit is operating normally. -- Standard condition to judge normal operation.
MEMO ENGLISH 53 S-east_MEMORY_IBIM_EN_03955A-02_EN.
MEMO 54 S-east_MEMORY_IBIM_EN_03955A-02_EN.
MEMO ENGLISH 55 S-east_MEMORY_IBIM_EN_03955A-02_EN.