Features of your new air conditioner Cool Summer Offer On those hot sweltering summer days and long restless nights, there is no better escape from the heat than the cool comforts of home. Your new air conditioner brings an end to exhausting hot summer days and lets you rest. This summer, beat the heat with your own air conditioner.
Safety precautions ENGLISH Before using your new air conditioner, please read this manual thoroughly to ensure that you know how to safely and efficiently operate the extensive features and functions of your new appliance. Because the following operating instructions cover various models, the characteristics of your air conditioner may differ slightly from those described in this manual. If you have any questions, call your nearest contact center or find help and information online at www. samsung.com.
Safety precautions This appliance must be properly grounded. Do not ground the appliance to a gas pipe, plastic water pipe, or telephone line. Failure to do so may result in electric shock, fire, an explosion, or other problems with the product. Never plug the power cord into a socket that is not grounded correctly and make sure that it is in accordance with local and national codes. FOR INSTALLATION CAUTION Install your appliance on a level and hard floor that can support its weight.
FOR USING WARNING FOR USING ENGLISH Failing to do so may result in electric shock or fire. In the event of a gas leak (such as propane gas, LP gas, etc.), ventilate immediately without touching the power line. Do not touch the appliance or power line. Do not use a ventilating fan. A spark may result in an explosion or fire. To reinstall the air conditioner, please contact your nearest service center.
AA precautions Safety FOR USING WARNING Do not use this air conditioner for long periods of time in badly ventilated locations or near infirm people. Since this may be dangerous due to a lack of oxygen, open a window at least once an hour. If any foreign substance such as water has entered the appliance, cut the power by unplugging the power plug and turning the circuit breaker off and then contact your nearest service center. Failing to do so may result in electric shock or fire.
FOR USING CAUTION FOR CLEANING ENGLISH Do not use this air conditioner to preserve precision equipment, food, animals, plants or cosmetics, or for any other unusual purposes. This may result in property damage. Avoid directly exposing humans, animals or plants from the air flow from the air conditioner for long periods of time. This may result in harm to humans, animals or plants.
Checking before use Operation ranges The table below indicates the temperature and humidity ranges the air conditioner can be operated within. Refer to the table for efficient use. MODE OPERATIONAL TEMPERATURE INDOOR OUTDOOR INDOOR HUMIDITY IF OUT OF CONDITIONS COOLING 18˚C to 32˚C -5˚C to 48˚C 80% or less Condensation may occur on the indoor unit with risk to have either water blow off or drops on the floor.
Tips on using air conditioner Here are some tips that you would follow when using your air conditioner. ENGLISH TOPIC RECOMMENDATION Cooling • I f current outside temperatures are much higher than the selected indoor temperature, it may take time to bring the inner temperature to the desired coolness. • Avoid drastically turning down the temperature. Energy is wasted and the room does not cool faster.
Viewing the parts Main parts Air flow blade Air intake Air filter (under the grille) Display Indicator On/Off operation indicator Removing frost indicator Timer indicator Filter reset indicator Remote control sensor NOTE 10 • Y our air conditioner and display may look slightly different from the illustration shown above depending on your model.
Cleaning and maintaining the air conditioner Cleaning the exterior CAUTION ENGLISH Wipe the surface of the unit with a slightly wet or dry cloth when needed. Wipe off dirt of odd-shaped area by using a soft brush. • D o not use Benzene or Thinner. They may damage the surface of the air conditioner and can create a risk of fire.
Cleaning and maintaining the air conditioner Cleaning air filter and grille Detach the front grille. Open the front grille. Pull both hooks and take the grille downward. Two safety clips are mounted to the front grille to prevent it from dropping. PULL Remove the safety clip from panel front. (There are two safety clips between grille and panel base.) If you want to clean the filter only, you do not have to detach the grille.
If the air conditioner will not be used for an extended period of time, dry the air conditioner to maintain it in best condition. Dry the air conditioner thoroughly by operating in Fan mode for 3 to 4 hours and disconnect the power plug. There may be internal damage if moisture is left in components. 4 hours. This helps remove odors which may have generated from dampness. Periodical checks Refer to the following chart to maintain the air conditioner properly.
Troubleshooting Refer to the following chart if the air conditioner operates abnormally. This may save time and unnecessary expenses. PROBLEM SOLUTION The air conditioner does not operate immediately after it has been restarted. • B ecause of the protective mechanism, the appliance does not start operating immediately to keep the unit from overloading. The air conditioner will start in 3 minutes. The air conditioner does not work at all. • C heck that the power plug is properly connected.
INSTALLATION PARTS Indoor AA Unit Installation 5. Check the level of the indoor unit by using a It is recommended to install the Y-joint before installing the indoor unit. 1. Place the pattern sheet on the ceiling at the spot where leveler. A tilt of the indoor unit may cause malfunction of a built-in float switch and water leaks. Since the diagram is made of paper, it may shrink or stretch slightly due to temperature or humidity.
Indoor AA Unit Installation Insulation Once you have checked that there are no leaks in the system, you can insulate the piping and hose. 1. To avoid condensation problems, place T13.0 or thicker Acrylonitrile Butadien Rubber separately around each refrigerant pipe. Note Always make the seam of pipes face upwards. No gap NBR(T13.0 or thicker) 2. Wind insulating tape around the pipes and drain hose avoiding to compress the insulation too much.
Wire work Flexible hose Installation Power and communication cable connection Be horizontal 1. Before wiring work, you must turn off all power source. 3. The power cable should be used only copper wires. Max. allowable axis gap Insulation Connect to indoor unit Insulation Indoor Unit Max. 30˚ Max. allowable bending angle Flexible hose (Apply adhesive on the outside) 4. Connect the power cable{1(L), 2(N)} among the units within maximum length and communication cable(F1, F2) each.
Setting AA an indoor unit address and installation option ▶ Set the indoor unit address and installation option with remote controller option. Set the each option separately since you cannot set the ADDRESS setting and indoor unit installation setting option at the same time.You need to set twice when setting indoor unit address and installation option. ▶ Please use the proper wireless remocon which can set 24 digit option code.
Option setting will be selected in rotation. SEG2 SEG3 SEG4 SEG5 SEG6 SEG8 SEG9 SEG10 SEG11 SEG12 SEG14 SEG15 ENGLISH 1. Setting SEG2, SEG3 option Press Low Fan button(∨) to enter SEG2 value. Press High Fan button(∧) to enter SEG3 value. Each time you press the button, … Status 2. Setting Cool mode Press Mode button to be changed to Cool mode in the ON status. 3. Setting SEG4, SEG5 option Press Low Fan button(∨) to enter SEG4 value. Press High Fan button(∧) to enter SEG5 value.
Setting an indoor unit address and installation option AA Option setting Status 12. Setting Cool mode Press Mode button to be change to Cool mode in the OFF status. 13. Setting SEG16, SEG17 option Press Low Fan button(∨) to enter SEG16 value. Press High Fan button(∧) to enter SEG17 value. Each time you press the button, … will be selected in rotation. SEG16 SEG17 SEG18 SEG20 SEG21 SEG22 SEG23 SEG24 14. Setting Dry mode Press Mode button to be change to Dry mode in the OFF status. 15.
Setting an indoor unit address (MAIN/RMC) Indoor Unit 1(L) 2(N) 1. Check whether power is supplied or not. F2 F1 - When the indoor unit is not plugged in, there should be additional power supply in the indoor unit. ENGLISH 2. The panel(display) should be connected to an indoor unit to receive option. 3. Before installing the indoor unit, assign an address to the indoor unit according to the air conditioning system plan. 4. Assign an indoor unit address by wireless remote controller.
AA Setting an indoor unit address and installation option Setting an indoor unit installation option (suitable for the condition of each installation location) 1. Check whether power is supplied or not. - When the indoor unit is not plugged in, there should be additional power supply in the indoor unit. 2. The panel(display ) should be connected to an indoor unit to receive option. 3. Set the installation option according to the installation condition of an air conditioner.
02 series installation option(Detailed) Option No.
Setting AA an indoor unit address and installation option Option Explanation SEG19 PAGE SEG20 Individual control of a remote controller SEG21 SEG22 SEG23 SEG24 Heating setting compensation EEV Step of stopped unit during oil return/ defrost mode Motion detect sensor - Remote Controller Display Indication Details Indication Details Indication Details Indication 0 or 1 channel 1 0 Disuse 2 channel 2 1 2°C 3 channel 3 0 Details Indication 0 Default value 1 2 3 4 Indication and Details
05 series installation option(Detailed) Option No. : 05XXXX-1XXXXX-2XXXXX-3XXXXX Option SEG2 PAGE SEG3 SEG4 Use of Auto Change Over for HR only in Auto mode MODE SEG5 (When setting SEG3) Standard heating temp. Offset SEG6 setting SEG3) (When setting SEG3) (When Standard for mode Standard cooling change temp.
Setting an indoor unit address and installation option AA SEG 3, 4, 5, 6, 8, 9 additional information Heating Thermo On Heating Thermo Off Cooling Thermo On Cooling Thermo Off When the SEG 3 is set as "1" and follow Auto Change Over for HR only operation, it will operate as follows. Standard temp. for Heating → Cooling Temp. c b Standard temp. for Cooling Ts B C D A Set temp. for Auto mode a Standard temp. for Heating d Standard temp.
Memo AA ENGLISH 27
QUESTIONS OR COMMENTS? COUNTRY CALL AUSTRIA 0810 - SAMSUNG (7267864, € 0.07/min) BELGIUM 02-201-24-18 BOSNIA 051 133 1999 OR VISIT US ONLINE AT www.samsung.com www.samsung.com/be (Dutch) MOLDOVA 0-800-614-40 www.samsung.com www.samsung.com/be_fr (French) U.A.E 800-SAMSUNG (726-7864) www.samsung.com OMAN 800-SAMSUNG(726-7864) KUWAIT 183-2255 (183-CALL) BAHRAIN 8000-4726 QATAR 800-2255 (800-CALL) EGYPT 08000-726786 www.samsung.com www.samsung.
4 Way Cassette Type Air Conditioner user manual This manual is made with 100% recycled paper. imagine the possibilities Thank you for purchasing this Samsung product. To receive more complete service, please register your product at www.samsung.