Product specifications
Model AM14A1(B1)E2 AM20A1(B1)E2
INDOOR UNIT OUTDOOR UNIT INDOOR UNIT OUTDOOR UNIT
Item AM14A1(B1)E07 UM14A1(B1)E2 AM20A1(B1)E08 AM20A1(B1)E06 UM20A1(B1)E3
Type Wall-Mounting Multi Split
Cooling 1 unit(A) 9,000 9,000
1 unit(B)
BTU/h
9,000 7,300
2 unit(A+B) 14,000 (7,000x2) 16,300 (9,000+7,300)
2 unit(B+C) - 10,800 (5,400+5,400)
3 unit(A+B+C)
- 19,800(9,000+5,400+5,400)
Dehumiditying I/h 1.2 - 1.6 1.1 -
Air volume Cooling m
3
/min 7.0 - 8.5 6.0 -
Noise Cooling dB 35 55 38 35 54
Power V-Hz 1-220-240V~, 50Hz
Power 1 unit(A) 1,100 1,010
Consumption 1 unit(B) 1,100 930
2 unit(A+B) W 1,200 1,800
2 unit(B+C) - 1,010
3 unit(A+B+C)
- 1,900
Operating 1 unit(A) 4.7 4.3
Current 1 unit(B) 4.7 3.9
2 unit(A+B) A 5.2 7.5
2 unit(B+C) - 4.3
3 unit(A+B+C)
- 8.2
Starting current A 30
Power cable(Option)
- H05RNF25 - H07RNF2.5
H05RNF (4G 1mm
2
) H05RNF (4G 1mm
2
)
Fuse capacity A 3.15 - 3.15 3.15 -
Outer
WidthxHeight
mm 815x298x182 720x525x245 815x298x182 745x260x177 787x620x320
dimension xDepth inch 32.08x11.73x7.17 28.35x20.67x9.65 32.08x11.73x7.17 29.33x10.23x6.96 30.98x24.41x12.6
Weight kg 9.6 35 9.6 8.0 54
Refrigerant Liquid
OD(mm)xL(m)
6.35x5 - 6.35x5 6.35x5 -
pipe Gas 9.52x5 - 9.52x5 9.52x5 -
Drain hose
ID(mm)xL(m)
17x2,000 17x2,000
Type - Rotary - Rotary
Model name - 48A124JV1E5 44B092JW1E6 44B102JW1EG -
Comp Capacitor 30µFx420VAC 30µFx370VAC 40µFx450VAC -
ressor
Motor
Type(model) - - - - -
Rated output W - 1210 895 950 -
Type Cross-fan Propeller Cross-fan Cross-fan Propeller
Blower
Motor
Type Resin Still Resin Resin Still
Rated output W 35 60 35 35 60
Heat exchanger 2Row 12Step 2Row 20Step 2Row 12Step 2Row 10Step 2Row 24Step
Refrigerant control unit
A+B-UNIT : Capillary Tube
A+B/C-UNIT : Capillary Tube + Solenoid valve
+ Solenoid valve
Freezer oil capacity - 410 360 350 -
Refrigerant to change(R-22) - 1,000 700 860 630/860
Protection device - MRA12030-12008 MRA12037-12007 MRA12054-12008 -
Standard Conditions ISO R5151 Standard ISO R5151 Standard
Samsung Electronics
2-1
2. Product Specifications
2-1 Table
Perfor-
mance
Power
Size
• The basic performance test is based on the piping of 5MT.(Be sure to check the installing conditions as extension of the piping may lead to
performance degradetion.)