Specifications

50 | SAMSUNG
FEATURES & OPERATION
6
6-2. Details for Operation Property
1. AUTO MODE : In this mode, operation mode(COOL, HEAT)
is selected automatically by the room temperature of initial
operation.
In case of Heat pump model.
In case of Cooling only model.
T= -1°C, -2°C, 0°C, +1°C, +2°C
T is controlled by setting temperature up/down key of
remote control
2. COOL MODE : The unit operates according to the difference
between the setting and room temperature. (18°C~30°C)
3. HEAT MODE(In case of Heat pump model) :
The unit operates according to the difference between the
setting and room temperature.(16°C~30°C)
*Prevention against cold wind : In order to prevent the cool
air from flowing out at the heat mode, the indoor fan does
not operate or operates very slowly in the following cases.
At this time, the indoor heat exchanger will be preheating.
- For 3~5 minutes after the initial operation
- For deicing operation
- The operation of an indoor fan in accordance with the
temperature of an indoor heat exchanger
*High temperature release function : It is a function to detect
an outdoor overload by the sensor of an indoor heat
exchanger and to turn the outdoor fan or the compressor
ON/OFF for safety.
*Deice : Deicing operation is controlled by indoor unit's
heat exchanger temperature and accumulating time of
compressor's operation.
Deice ends by sensing of the processing time by deice
condition.
4. DRY MODE : Has 3 states, each determined by room
temperature.
The unit operates in DRY mode.
*Compressor ON/OFF Time is controlled compulsorily(can
not set up the fan speed, always breeze).
*Protective function : Low temperature release. (Prevention
against freeze)
5. TURBO MODE : This mode is available in AUTO, COOL,
HEAT, DRY, FAN MODE.
When this button is pressed at first, the air conditioner is
operated "powerful" state for 30 minutes regardless of the
set temperature, room temperature.
When this button is pressed again, or when the operating
time is 30 minutes, turbo operation mode is canceled and
returned to the previous mode.
*But, if you press the TURBO button in DRY or FAN mode
that is changed with AUTO mode automatically.
6. SLEEP MODE : Sleep mode is available only in COOL or
HEAT mode.
The operation will stop after 6 hours.
*In COOL mode : The setting temperature is automatically
raised by 1°C each 1hourWhen the temperature has been
raised by total of 2°C, that temperature is maintained.
*In HEAT mode : The setting temperature is automatically
dropped by 1°C each 1hour.
When the temperature has been dropped by total of 2°C,
that temperature is maintained.
7. FAN SPEED : Manual (3 step), Auto (4 step)
Fan speed automatically varies depending on both the
difference between setting and the room temperature.
8. COMPULSORY OPERATION :
For operating the air conditioner without the remote control.
*The operating is the same function that AUTO MODE in the
remote control.
Room Temp Operation Type
Tr 21°C+T Cool Operation (Set Temp:24˚C+T)
21°C +T>Tr Heat Operation (Set Temp:22˚C+T)
Operation Type Room Temp.
Cool Operation
Tr 25°C+T Compressor ON
Tr 24°C+T Compressor OFF
The temperature of
indoor heat exchanger
below 28˚C
28˚C~below 34˚C
34˚C~below 40˚C
above 40˚C
Indoor fan speed
off
LL Speed
L Speed
Setting Speed
Details for Operation Property
DB98_16444A(1)_1 2/9/04 10:04 AM Page 50