Specifications
56 | SAMSUNG
FEATURES & OPERATION
6
Details for Operation Property (cont.)
6-2-10. Indoor fan control in the Heating Mode
Indoor fan is controlled depending on the temperature of indoor heat exchanger in the heating mode.
●
INDOOR FAN CONTROL
The temperature of indoor heat exchanger Indoor fan speed
below 28°Coff
28°C ~ below 34°C LL speed
34°C ~ below 40°C L speed
above 40°C setting speed
When compressor is on
40°C
34°C
28°C
20°C
Setting speed
L Speed
LL Speed
OFF
Compressor
OFF OFF
UL
ON
When compressor is off
◆ When compressor begins operating
The temperature of indoor heat exchanger Indoor fan speed
above 20°C UL speed
below 20°Coff
after 10 minutes when compressor stops operating off
◆ When compressor stops operating
DB98_16444A(1)_1 2/9/04 10:04 AM Page 56