User manual

35
ENGLISH
Purging the indoor unit
1. Make sure that you have all the required tools (pipe cutter, reamer, aring tool and pipe holder).
2. If you want to shorten the pipe, cut it using a pipe cutter, ensuring that the cut edge remains at 9 with the side of the
pipe (see below examples of correct and incorrect cut edges).
3. To prevent a gas leak, remove all burrs at the cut edge of the pipe using a reamer.
4. Put aare nut slightly into the pipe and modify the are.
Thelengthofthepipecanbe:
•Extendedupto:seetablepage28
•Shortenupto:seepage28
Ifyouneedapipelongerthan5meters:
• Youmustextendtheassemblycable.
• Youmustaddrefrigeranttothepipes;otherwise,theindoorunitmayfreeze.
Unscrew the capsPipes
Oblique Rough Burr
Pipe
cutter
Pipe
• TheremainingairintheRefrigerationcycle,whichcontainsmoisture,
may cause malfunction on the compressor.
• Alwayscontacttheservicecenteroraprofessionalinstallationagency
for product installation.
• Topreventdirtorforeignsubstancesfromgettingintothepipesduring
installation, do NOT remove the caps completely until you are ready to
connect the pipes.
Cutting or extending the pipe
Outer Diameter (D) Depth (A) Flaring Size (B)
ø6.35 mm 1.3 mm 9.0 mm
ø9.52 mm 1.8 mm 13.0 mm
ø12.70 mm 2.0 mm 16.2 mm
ø15.88 mm 2.2 mm 19.3 mm
ø19.05 mm 2.2 mm 22.5 mm
ø22.23 mm 2.2 mm 25.7 mm
Pipe Flare
• Facethepipedownwhileremovingtheburrstomakesurethatburrsdonotgetintothepipe.
1. Unscrew the caps at the end of each pipe.
All inert gas exhausts from the indoor unit.
The indoor unit is supplied with inert gas (nitrogen).
Before installing the unit, check if nitrogen gas ow out of indoor unit.
If this one isn’t true, DO NOT INSTALL THE UNIT since leakage could be inside the indoor unit.
Boracay ET_AR09FSFT@_IBIM_DB68-03377A_EN-7.indd 35 2014/12/11 17:23:09