AR✴✴JCSD✴✴ Series AR✴✴FSSSBWK Series AR✴✴FSSSCURSeries AR✴✴JPSD✴✴ Series Air Conditioner user user & & installation installation manual manual This manual is made with 100% recycled paper. imagine imagine the the possibilities possibilities Thank you for purchasing this Samsung product. Thank you for purchasing this Samsung product. To receive more complete service, please register your product at www.samsung.com/register DB68-04953A-01 HC_BETTER_A3050_IB&IM_EN_DB68-04953A_UX.
Features of your new air conditioner 2-step cooling 2-step cooling function will quickly cool the room to reach the desired temperature and then it will adjust the fan speed and air flow direction automatically to help you stay comfortable and refreshing.
Contents Preparation Safety precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Checking before use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Safety precautions Before using your new air conditioner, please read this manual thoroughly to ensure that you know how to safely and efficiently operate the extensive features and functions of your new appliance. Because the following operating instructions cover various models, the characteristics of your air conditioner may differ slightly from those described in this manual. If you have any questions, call your nearest contact center or find help and information online at www.samsung.com.
FOR INSTALLATION 01 Preparation Do not install this appliance near a heater, inflammable material. Do not install this appliance in a humid, oily or dusty location, in a location exposed to direct sunlight and water (rain drops). Do not install this appliance in a location where gas may leak. This may result in electric shock or fire. Never install the outdoor unit in a location such as on a high external wall where it could fall.
Safety precautions FOR POWER SUPPLY CAUTION When not using the air conditioner for a long period of time or during a thunder/lightning storm, cut the power at the circuit breaker. Failing to do so may result in electric shock or fire. FOR USING WARNING If the appliance is flooded, please contact your nearest service center. Failing to do so may result in electric shock or fire.
FOR USING 01 Preparation Do not insert your fingers or foreign substances into the outlet when the air conditioner is operating. Take special care that children do not injure themselves by inserting their fingers into the product. Do not touch the air flow blade with your hands or fingers during the heating operation. This may result in electric shock or burns. Do not insert your fingers or foreign substances into the air inlet/outlet of the air conditioner.
Safety precautions FOR USING CAUTION Do not place objects or devices under the indoor unit. Water dripping from the indoor unit may result in fire or property damage. (example electrical appliances) Check that the installation frame of the outdoor unit is not broken at least once a year. Failing to do so may result in injury, death or property damage. Max current is measured according to IEC standard for safety and current is measured according to ISO standard for energy efficiency.
FOR CLEANING 01 Preparation This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance. WARNING Do not clean the appliance by spraying water directly onto it.
Checking before use Operation ranges The table below indicates the temperature and humidity ranges the air conditioner can be operated within. Refer to the table for efficient use.
Checking the name of the parts Your air conditioner may slightly look different from illustration shown below depending on your model.
Checking the remote controller • Point the remote controller towards the remote controller receiver of the indoor unit. • When you properly press the button on the remote controller, you will hear beep sound from the indoor unit and a transmit indicator( ) appears on the remote controller display.
Remote controller display Transmit indicator Operation mode indicator Low battery indicator 02 Basic function Set temperature/ Time (for Timer option) indicator Fan speed indicator good'sleep indicator Vertical/Horizontal air swing indicator Options indicator This function is not available in this model. Settings indicator • M ake sure that the water does not get to the remote controller. • The following function are displayed on the remote controller display but not supported in this model.
Basic function Basic operation is an operation mode that can be selected by pressing the Mode button. Auto In Auto mode, the air conditioner will automatically set the temperature and fan speed depending on the room temperature. Cool In Cool mode, the air conditioner will cool your room. You can adjust the temperature and the fan speed to feel cooler in hot season.
Basic function button to turn on the air conditioner. Press the button to set the operating mode. • Each time you press the Mode button, the mode will change in order of Auto, Cool, Dry, Fan and Heat. Press the Press the 02 Basic function Press the button to adjust the temperature. Auto You can adjust the set temperature by 1 °C within the range of 16 °C~30 °C. Cool You can adjust the set temperature by 1 °C within the range of 16 °C~30 °C.
Adjusting the air flow direction This function will allow you to adjust the air flow direction vertically and/or horizontally. Press the or button to make air flow blades vertically and/or horizontally. Vertical air flow Horizontal air flow ffTo keep the air flow direction in a constant direction, press the or button again. The air flow blade(s) will stop the movement. ffIf you adjust the vertical air flow blade manually, it may not close completely when you turn off the air conditioner.
Setting the On/Off timer Setting the On timer When the air conditioner is off; Cancel ffPress the Timer button select (On) press the set the timer to press the SET button. ffPress the Power ( ) button. or 03 TIMER 1. Press the Timer button to select (On). -- (On) indicator will keep blinking and you can set the time. 2. Press the , button to set the time. -- You can set the time in half hour unit from 30 minutes (0.5 on the display) ~ 3 hours and hour unit from 3~24 hours.
Setting the On/Off timer Setting the Off timer When the air conditioner is on; 1. Press the Timer button to select (Off). -- (Off) indicator will keep blinking and you can set the time. 2. Press the , button to set the time. -- You can set the time in half hour unit from 30 minutes (0.5 on the display) ~ 3 hours and hour unit from 3~24 hours. -- Time can be set from minimum 30 minutes to maximum 24 hours. 3. Press the SET button to complete the Off timer setting.
mode For a comfortable sleep, the air conditioner will operate in 3 stages in order of Fall asleep Sound sleep Wake up stage. When the air conditioner is operating in Cool/Heat mode; 03 TIMER 1. Press the Timer button to select ( ). -- ( ) indicator will keep blinking and you can set the time. 2. Press the , button to set the time. -- You can set the time in half hour unit from 30 minutes (0.5 on the display) ~ 3 hours and hour unit from 3~12 hours.
2-Step cooling function 2-Step Cooling function will set the air conditioner to cool the room quickly to reach the set temperature when the indoor temperature is higher than the set temperature, and then the air conditioner will automatically operate in Dry mode when indoor temperature reaches set temperature. When the air conditioner is operating in Cool mode; 1. Press the Options button. 2. Press the , or Options button until (2-Step) indicator starts to blink. 3.
Using the Fast function You can set the Fast function to provide fast and powerful cooling. When the air conditioner is operating in Cool mode; Cancel 04 OPTIONS 1. Press the Options button. 2. Press the , or Options button until (Fast) indicator starts to blink. 3. Press the SET button to set the Fast function. -- (Fast) (Fast) indicator will be displayed on the remote controller display and Fast function will begin.
Using the Single user function This function will reduce the energy usage while the air conditioner is operating in Cool mode. When the air conditioner is operating in Cool mode; 1. Press the Options button. 2. Press the , or [Options] button untill (Single user) indicator starts to blink. 3. Press the SET button to set the Single user function. -- (Single user) (Single user) indicator will be displayed on the remote controller display.
Using the Virus Doctor function This function will produce positive ions and supply them into the airflow. When the air conditioner is operating; Cancel 04 OPTIONS 1. Press the Options button. 2. Press the , or Options button until ( ) indicator starts to blink. 3. Press the SET button to set the Virus Doctor function. -- ( )( ) indicator will be displayed on the remote controller display and Virus Doctor function will begin.
Checking the usage time This function will displayed the accumulated operation time from the moment the air conditioner was turned on to the point when the usage function has been selected. When the air conditioner is operating; 1. Press the Settings button. 2. Press the , or Settings button until (Usage) indicator starts to blink. 3. Press the SET button to check the usage time. -- 3 seconds after setting usage time checking function, (Usage) indicator on the remote controller will disappear.
Setting the Beep sound Beep sound from the indoor unit can be muted. 05 SETTINGS 1. Press the Settings button. 2. Press the , or Settings button until (Beep) indicator starts to blink. 3. Press the SET button to mute the beep sound. - 3 seconds after setting Beep sound function, (Beep) indicator on the remote controller display will disappear and Beep sound function will begin.
Cleaning the air conditioner CAUTION • Make sure to turn off the power of the indoor unit and cut-off the power supply before cleaning the air conditioner. Cleaning the indoor unit Clean the product with a tepid damp cloth. ffRemove the dust accumulated in the gap of the product with a soft brush. • C ontact the service center when you clean the indoor unit heat exchanger because it needs to be disassembled. • Do not clean the display using alkaline detergent.
Cleaning the air conditioner Removing the Air filter Air filter 06 others There is a hole on the bottom right side of the filter. Put your finger in that hole to get a grip on the filter and slightly push it up to release the hooks from the bottom side. Then, pull it down to remove the filter from the main body. Cleaning the Air filter Washable foam based air filter captures large particles from the air. The filter is cleaned with a vacuum or by hand washing. Remove the Air filter from the main body.
Cleaning the air conditioner Reassembling the Air filter 1. Put the filter on the main body and insert the hooks which are in the top of the Air filter into the main body. ➀ Air filter 2. There’s one hook in both side of the filter, press the surface of the Air filter softly and get the hooks into the main body. ➁ 3. Press the bottom of the filter lightly to securely fix the main body. ➂ ➃ ➄ English-28 HC_BETTER_A3050_IB&IM_EN_DB68-04953A_UX.
Maintaining the air conditioner If the air conditioner will not be used for an extended period of time, dry the air conditioner to maintain it in best condition. 06 others 1. Dry the air conditioner thoroughly by operating in Fan mode for 3 to 4 hours and cut-off the power supply. There may be internal damage if moisture is left in components. 2. Before using the air conditioner again, dry the inner components of the air conditioner again by running in Fan mode for 3 to 4 hours.
Troubleshooting Refer to the following chart if the air conditioner operates abnormally. This may save time and unnecessary expenses. PROBLEM SOLUTION The air conditioner • Check power status and then operate the air conditioner again. does not work at all. • P lug in or switch on the circuit breaker and then operate the air conditioner again. • Ensure Isolator is switch on. • Check if you have set the Off Timer. Operate the air conditioner again by pressing the Power button.
Troubleshooting SOLUTION Fan speed adjustment is not working. mode. In • C heck if you have selected Auto/Dry/Fast/ these mode, fan speed is set to Auto and you cannot adjust the fan speed. 06 others PROBLEM Remote controller is • Check if your batteries are depleted. not working. • Make sure nothing is blocking your remote controller sensor. • Check that there are strong lighting apparatus near the air conditioner.
Safety precautions Carefully follow the precautions listed below because they are essential to guarantee the safety of the equipment. • Always disconnect the air conditioner from the power supply before servicing it or accessing its internal components. • Verify that installation and testing operations are performed by qualified personnel. • Verify that the air conditioner is not installed in an easily accessible area.
Installing the unit IMPORTANT: When installing the unit, always remember to connect first the refrigerant tubes, then the electrical lines. Always disassemble the electric lines before the refrigerant tubes. Upon receipt, inspect the product to verify that it has not been damaged during transport. If the product appears damaged, DO NOT INSTALL it and immediately report the damage to the carrier or retailer (if the installer or the authorized technician has collected the material from the retailer.
Choosing the installation location Outdoor Unit Where it is not exposed to strong wind Well ventilated and dustless places Where possible keep out of sunlight and rain Where neighbors are not annoyed by operation sound or hot air Solid wall or support that prevents vibration and is strong enough to hold the product weight Where there is no risk of flammable gas leakage When installing the unit at a high place be sure to fix the unit legs 3 m or more away from the TV or radio (to pre
Space Requirements for Outdoor Unit When installing 1 outdoor unit Top view 07 installation Figure Description Side view Air intake Air outlet Air intake Air outlet , Air flow direction.
Choosing the installation location (Unit : mm) 500 or more 600 or more 1500 or more 600 or more 300 or more 500 or more When the upper part of the outdoor unit and the air outlet is opposite the wall 300 or more When the walls are blocking front and the rear side of the outdoor units 300 or more When front and rear side of the outdoor unit is towards the wall 1500 or more 600 or more 3000 or more 3000 or more 200 or more • I f installation is done in inappropriate space, unit may g
• T he flare nuts are attached to the end of each pipe of an evaporator or a service port. Use the nuts when connecting the pipes. • The wire assembly cable is optional. If it is not supplied, use the standard cable. • The drain plug and rubber leg are only included when the air conditioner is supplied without the assembly pipe as seen in the picture below. Insulated Assembly Pipe, Ø6.35 mm x 5 m (1) Insulated Assembly Pipe, Insulated Assembly Pipe, Ø15.88 mm x 5 m (1) Ø12.
1. Disassemble the cover panel as described in page 39~40. 2. Remove the Hanger plate from the indoor unit. (1) Unscrew 2 screws that fixes the Hanger plate to the indoor unit. (2) Push the hooks (on the bottom part of the indoor unit) up to release the installation plate from the hooks that holds it. (3) Pull the installation plate to release it completely from the indoor unit. Screw(M4x10) Screw 3.
Disassembling/Assembling the Cover panel for indoor unit installation In order to install the indoor unit, you must disassemble the cover panel first. Please proceed following instructions to disassemble and assemble the cover panel. Hooks (on the cover panel) may get damaged if you apply excessive force as you disassemble and assemble the cover panel. Please follow the following instructions. 07 installation Please scan this QR code for detail video of indoor unit installation.
Disassembling/Assembling the Cover panel for indoor unit installation ffRemoving the hooks on the side ② ffRemoving the hooks on the central part ① Caution (fragile) -- Gently press the both side of the cover panel inwards (①) and release the hooks on both sides(②). Caution (fragile) -- Use both hands -- Release each hook by pushing it up at an angle. Assembling the Cover panel (After mounting the indoor unit) To assemble the Cover panel, proceed in reverse order of disassembling.
Connecting the assembly cable Cable specification Power cable Interconnection cable 13JC 3G x 1.0 mm², H05VV-F 3G x 1.0 mm², H07RN-F 13JP 3G x 1.0 mm², H05VV-F 5G x 1.0 mm², H07RN-F 19/25JC 3G x 2.5 mm², H05VV-F 3G x 2.5 mm², H07RN-F 19JP 3G x 1.5 mm², H05VV-F 5G x 1.5 mm², H07RN-F 3G x 2.5 mm², H05VV-F 3G x 2.5 mm², H07RN-F 2 x 0.75 mm², H05RN-F 25JP Type GL 07 installation Model 20 A 25 A • C onnect the power cable to the auxiliary circuit breaker.
Connecting the assembly cable When you install the unit, make first refrigerant connections and then electrical connections. Connect the air conditioner to grounding system before performing the electrical connection. If unit is uninstalled, first disconnect electrical cables, then refrigerant connections. If the outdoor unit is more than 5 meters away from the indoor unit, you must extend the cable. The maximum length of the cable is 15(13/19) / 20(25) meters. 1.
Installing and connecting the assembly pipe of the indoor unit Connect indoor and outdoor units with field-supplied copper pipes by means of flare connections. Use insulated seamless refrigeration grade pipe only, (Cu DHP type according to ISO1337), degreased and deoxidized, suitable for operating pressures of at least 4200 kPa and for burst pressure of at least 20700 kPa. Under no circumstances must sanitary type copper pipe be used.
Evacuating the indoor unit The indoor unit is supplied with inert gas (nitrogen). Before installing the unit, check if nitrogen gas flow out of indoor unit. If this one isn’t true, DO NOT INSTALL THE UNIT since leakage could be inside the indoor unit. 1. Unscrew the caps at the end of each pipe. All inert gas exhausts from the indoor unit. • T o prevent dirt or foreign substances from getting into the pipes during installation, do NOT remove the caps completely until you are ready to connect the pipes.
Cutting or extending the pipe 5. Check if you flared the pipe correctly (see examples of incorrectly flared pipes below). Inclined Damaged Surface Cracked Uneven Thickness 6. Align the pipes to connect them easily. Tighten the flare nuts first with your hands, and then with a torque wrench, applying the following torque: Torque Flare nut Outer Diameter N•m kgf•cm ø6.35 mm 14~18 140~180 ø9.52 mm 34~42 350~430 ø12.70 mm 49~61 500~620 Indoor outlet pipe Connecting pipe ø15.
Installing and connecting the drain hose of the indoor unit 5cm less After completing the installation of the drain hose, pour water into the drain pan to check whether the hose is well drained. Ditch Keep a clearance of at least Do not place the end of the 5 cm between the end of the drain hose in a hollow. drain hose and the ground. 1) Correct connection Drain hose 2) Incorrect connection Pipe Drain hose Pipe • D on’t tie drain hose to the assembly pipe which may lead to water leakage.
Installing and connecting the drain hose of the indoor unit Extension drain hose • T he hose will be fixed permanently into position after finishing the installation and the gas leak test; refer to page 51 for further details. 07 installation 6. Pass the drain hose under the refrigerant pipe, keeping the drain hose tight. Shield 7. Pass the drain hose through the hole in the wall. Check if it slants downwards as seen in the picture. 8. Using natural drainage method, check the drainage is normal.
Installing and connecting the drain hose of the outdoor unit While heating, ice may accumulate. During the process of defrosting, check if condensation draining is adequate. For adequate draining, do the following. 1. Insert the drain plug into the drain hole on the underside of the outdoor unit. • T o avoid drain plug from contacting the ground, secure gap between the ground and the bottom surface of the outdoor unit. Drain plug Drain hole Bottom surface of outdoor unit 2.
Evacuating the connected pipes 1. Connect each assembly pipe to the appropriate valve on the outdoor unit and tighten the flare nut. Outdoor unit Indoor unit Gas pipe side • Excessive torque can be cause of gas leakage. Liquid pipe side Torque N•m kgf•cm 14~18 140~180 34~42 350~430 49~61 500~620 68~82 690~830 Outer Diameter 3. Connect the charging hose of the low-pressure side of manifold gauge to a gas service port as seen in the picture. 4.
Performing the gas leak tests Make sure to check for gas leaks before completing the installation process (connecting the assembly pipe and hose between indoor unit and outdoor unit, insulating the cables, hose and pipe, and fixing the indoor unit to the installation plate). A D C B Test part for outdoor unit Test part for indoor unit Tightening torque for body cap (Refer to the table) Before inspecting the leakage, use a torque wrench to close the cap for the service valve.
Fixing the indoor unit in place Perform the following work on the area where gas leak test was done priory. After checking for gas leaks in the system, insulate the pipe, hose and cables. Then place the indoor unit on the installation plate. Insulation Pipes 2. Wind the pipe, assembly cable and drain hose with vinyl tape. 3. Place the bundle (the pipe, assembly cable and drain hose) in the lower part of the indoor unit carefully so it does not project from the rear of the indoor unit. 4.
Smart Install mode This model supports Smart Install mode which checks installation status to find out if there is any problems with any of the functions. Execute Smart Install mode after installation. 1. Check the installation status of the air conditioner. 1) Check the power supply, service valve (if it's open), power cable of the indoor and outdoor unit and amount of additional refrigerant required for pipe extension. 2) Status of the indicator after supplying the power : Standby status 2.
1) Smart Install mode in progress • 88 Display : Progress will be displayed in 0~99. • LED Display : Indicator on the indoor unit display will blink in sequence and then all indicators will blink. (This will be repeated.) TYPE 88 Display LED Display ❋❋ Display may be different depending on the model. 07 installation LED1 LED2 LED3 Indoor unit indicator 1. Smart Install mode will end. 1) Smart Install mode will take approximately 7~13 minutes. (Actual time may be different depending on the model.
Final check and trial operation To complete the installation, perform the following checks and tests to ensure that the air conditioner operates correctly. Check the followings : • Strength of the installation site • Tightness of pipe connection to detect gas leak • Electric wiring connection • Heat-resistant insulation of the pipe • Drainage • Grounding conductor connection • Correct operation (follow the steps below) 1.
How to connect your extended power cables I tems to prepare (compressor and insulation tape should be prepared by an installation technician.) Crimping pliers Connection sleeve (mm) Insulation tape Contraction tube (mm) MH-14 20xØ7.0(HxOD) Width 18 mm 50xØ8.0(LxOD) Shape 1. As shown in the figure, peel off the shields from the rubber/wire of the power cable. - Peel off 20 mm of the wire shields of the tube installed already.
QUESTIONS OR COMMENTS? COUNTRY CALL OR VISIT US ONLINE AT IRAN 021-8255 [CE] 021-42132 [HHP] www.samsung.com/iran/support SAUDI ARABIA 8002474357 www.samsung.com/sa/support www.samsung.com/sa_en/support U.A.E 800-SAMSUNG (800 - 726 7864) www.samsung.com/ae/support www.samsung.com/ae_ar/support QATAR 800-CALL (800-2255) www.samsung.com/ae/support www.samsung.com/ae_ar/support BAHRAIN 8000-GSAM (8000-4726) www.samsung.com/ae/support www.samsung.