Cooling only AVMKH020CA0(1) AVMKH032CA0(1) AVMKH040CA0(1) AVMKC020CA0(1) AVMKC032CA0(1) AVMKC040CA0(1) ENGLISH FRANÇAIS Heat pump ESPAÑOL OWNER’S INSTRUCTIONS MANUAL DE INSTRUCCIONES MANUEL D’UTILISATION System Air Conditioner Aire acondicionado sistemático Climatiseur numérique multifonctionnel E S F DB98-05585A(2)
Safety Precautions WARNING DANGER CAUTION E-2 ◆ If the power supply cord of this air conditioner is damaged, it must be replaced by the manufacturer or its authorized service personnel only in order to avoid a safety hazard. ◆ Do not attempt to install this air conditioner by yourself. ◆ This unit contains no user-serviceable parts. Always consult authorized service personnel for repairs. ◆ When moving, consult authorized service personnel for disconnection and installation of the unit.
ENGLISH Contents ◆ PREPARING YOUR AIR CONDITIONER ■ Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ■ View of the Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ■ Wireless Remote Controller-Buttons and Display . . . . . . . . . . . ■ Wired Remote Controller-Buttons and Display . . . . . . . . . . . . . ■ Centralized Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
View of the Unit The figures are shown in this instruction may differ from yours depending on the model.
ENGLISH Outdoor Unit TYPE A Air outlet Connection valve Outdoor Unit TYPE B Air outlet Connection valve Outdoor Unit TYPE C Air outlet Connection valve Outdoor Unit TYPE D Air outlet Connection valve Outdoor Unit TYPE E Air outlet Connection valve Note If the heat exchanger in the outdoor unit gets dusty, cooling efficiency may fall. So clean the heat exchanger with water when it becomes dirty. However, be careful when you wash the surface of the heat exchanger because it is very sharp.
Wireless Remote Controller-Buttons and Display The wireless remote controller is an optional accessory. To use the wireless remote controller, refer to an appropriate manual.
Wired Remote Controller-Buttons and Display ENGLISH The wired remote controller is an optional accessory and it is installed on the wall. To use the wired remote controller, refer to an appropriate manual.
Centralized Controller The centralized controller is an optional accessory and it is installed on the wall. To use the centralized controller, refer to an appropriate manual. Operating lamp All On button All Off button On/Off indicators On/Off buttons Index Note E-8 Operating lamp comes on when at least one air conditioner connected to the centralized controller is operating.
ENGLISH Operating Recommendations Here are a few recommendations that you should follow when operating your air conditioner. Topic Recommendation Heating performances The heat pump function of the air conditioner absorbs heat from outside air and brings it indoors. As the temperature of the outside air drops, the heating performance of air conditioner will decrease. If you find that the room is not warm enough, using an additional heating appliance is recommended.
Temperature and Humidity Ranges The following table indicates the temperature and humidity ranges, within which the air conditioner can be used. If the air conditioner is used at... Then... High temperature The automatic protection feature may be triggered and the air conditioner stopped. Low temperature A water leakage or some other malfunction may happen if the heat exchanger freezes.
ENGLISH Cleaning Your Air Conditioner To get the best possible use out of your air conditioner, you must clean it regularly to remove the dust that accumulates on the air filter. IMPORTANT 1 Open the front grille by pushing the tabs on the grille. IMPORTANT 2 Before cleaning your air conditioner, ensure that you have switched off the electric circuit breaker used for the unit. You must give attention when disassembling the front grille and must check the safety clips have been installed.
Bio-Pure Filter Installation (Optional) The air conditioner can be fitted with a Bio-Pure or deodorizing filter to remove minute dust particles or odours. The service life of the filter is approximately three months depending on the time during which the air conditioner is used. 1 Bio-pure filter Remove the vinyl packing from the filter. Note Do not remove the packing from a bio-pure filter until you wish to use the filter, as it will lose its properties.
ENGLISH Solving Common Problems Before contacting the after-sales service, perform the following simple checks. They may save your time and expense of an unnecessary call. Problem Explanation/Solution The air conditioner does not ◆ Check that the breaker used for the air conditioner is switched on. operate at all Wired Remote Controller The air conditioner does not ◆ is displayed on the wired remote controller. In this case, operate with the remote turn the air conditioner off and contact your dealer.
Technical Specifications Model Power Supply AVMKH020CA0(1) AVMKH032CA0(1) AVMKH040CA0(1) 1Ø, 208-230V~, 60Hz AVMKC020CA0(1) AVMKC032CA0(1) AVMKC040CA0(1) E-14
ENGLISH Memo E-15
THIS AIR CONDITIONER IS MANUFACTURED BY: ESTE AIRE ACONDICIONADO HA SIDO FABRICADO POR: CE CLIMATISEUR EST FABRIQUE PAR: ELECTRONICS Printed in Korea