Datasheet

General Capacitors
NO ITEM PERFORMANCE TEST CONDITION
15
High
Temperature
Resistance
Appearance No mechanical damage shall occur.
Applied Voltage : 200%* of the rated voltage
Temperature : max. operating temperature
Duration Time : 1000 +48/-0 Hr.
Charge/Discharge Current : 50
max.
* refer to table(3) : 150%/100% of the rated
voltage
Perform the initial measurement according to
Note1 for Class
Perform the final measurement according to
Note2.
Capacitance
Characteristics Capacitance Change
Class
Within ±3% or ±0.3
,
Whichever is larger
Class
A(X5R)/
B(X7R)
Within ±12.5%
X(X6S) Within ±25%
F(Y5V)
Within ±30%
Within ±30%
Q
(Class
)
Capacitance
30
:Q
350
10
Capacitance <30
:Q
275 + 2.5×C
Capacitance < 10
:Q
200 +10×C (C: Capacitance)
Tan
δ
(Class
)
1. Characteristic : A(X5R),
B(X7R)
0.05max
(16V and over)
0.075max (10V)
0.075max
(6.3V except Table 1)
0.125max*
(refer to Table 1)
2. Characteristic : F(Y5V)
0.075max
(25V and over)
0.1max(16V, C<1.0
)
0.125max(16V, C
1.0
)
0.15max ( 10V)
0.195max (6.3V)
X(X6S) 0.11max (6.3V and below)
Insulation
Resistance
1,000
or 50
·
whichever is smaller.
16
Temperature
Cycle
Appearance No mechanical damage shall occur.
Capacitor shall be subjected to 5 cycles.
Condition for 1 cycle :
Step Temp.(
) Time(min.)
1
Min. operating
temp.+0/-3
30
225 2~3
3
Max. operating
temp.+3/-0
30
425 2~3
Leave the capacitor in ambient condition
for specified time* before measurement
*22hours(Class
)
24 ± 2 hours (Class
)
Capacitance
Characteristics Capacitance Change
Class
Within ±2.5% or ±0.25
Whichever is larger
Class
A(X5R)/
B(X7R)/
Within ±7.5%
X(X6S) Within ±15%
F(Y5V) Within ±20%
Q
(Class
)
Within the specified initial value
Tan
δ
(Class
)
Within the specified initial value
Insulation
Resistance
Within the specified initial value
RELIABILTY TEST CONDITION