Specifications
Table Of Contents
- DCS 400si General Description
- Table of Contents
- Part 1. System Overview
- Part 2. Hardware Descriptions
- 2.1 Main Cabinet
- 2.2 Expansion Cabinet
- 2.3 Common Control Cards
- 2.4 Interface Cards
- 8 Universal Trunk Card (D8UTK)
- 16 Circuit Trunk Card (D16TK)
- Digital Trunk Card (DTPRI)
- 8 BRI (Basic Rate Interface-D8BRI)
- 24 Digital Line Interface (D24DL)
- 16 Single Line Interface with Message Waiting (D16SL)
- 24 Single Line Interface (D24SL)
- Keyset Daughterboard -DLI (KDb-DLI)
- Keyset Daughterboard -SLI (KDb-SLI)
- Auto Attendant / UCD (DAAUP)
- Miscellaneous Applications Processor 1 (DMAP1)
- 2.5 Power Supply (DPCU)
- 2.6 System Daughterboards
- 2.7 Station Equipment
- Part 3. Specifications
- Part 4. Features
- System Features
- 4.1 System Feature Descriptions
- Account Code Entry
- All Call Voice Page
- Attention Tone
- Authorization Codes
- Auto Attendant
- Automatic Hold
- Background Music
- CADENCE - Integrated Voice Mail
- Call Costing
- Caller Identification
- Call Forwarding
- Call Hold (Exclusive)
- Call Park and Page
- Call Pickup
- Call Waiting / Camp-On
- Centrex / PBX Use
- Chain Dialing
- Class of Service
- Common Bell Control
- Conference
- Computer Telephony Integration (CTI)
- Customer Set Relocation
- Data Security
- Database Printout
- Dialed Numbe Identification Service (DNIS)
- Direct In Lines
- Direct Inward Dialing (DID) T1/Copper
- Direct Inward System Access (DISA)
- Direct Trunk Selection
- Directory Names
- DISA Security
- Distinctive Ringing
- Door Lock Release (Programmable)
- Door Phones
- E & M Tie Lines (T1/Copper)
- Executive Barge-In (Override)
- Executive / Secretary Pooling
- External Music Interfaces
- External Page Interfaces
- Flash Key Operation
- Flexible Numbering
- Ground Start Trunks (T1/Copper)
- Hot Line
- In Group / Out of Group
- Incoming Call Distribution
- Incoming / Outgoing Service
- Individual Line Control
- ISDN Service
- Least Cost Routing
- Live System Programming
- Meet Me Page and Answer
- Memory Protection
- Message Waiting Indications
- Microphone On / Off Per Station
- Music On Hold - Flexible
- Off Premises Extensions (OPX)
- Operator Group
- Overflow
- Paging
- Park Orbits
- Power Failure Transfer
- Prime Line Selection
- Private Lines
- Programmable Line Privacy
- Programmable Timers
- Recalls
- Remote Programming-PC
- Ring Modes
- Ring Over Page
- Single Line Connections
- Speed Dial Numbers (2500)
- Speed Dial by Directory
- Station Hunt Groups (50)
- Station Message Detail Recording (SMDR)
- Station Pair
- Station to Station Restriction
- System Alarms
- System Maintenance Alarms
- System Directory
- Tenant Service (2)
- Toll Restriction
- Toll Restriction Override
- Tone or Pulse Dialing
- Traffic Reporting
- Transfer
- Trunk Groups (49)
- Uniform Call Distribution (UCD)
- Universal Answer
- Voice Mail Integration
- Walking Class of Service
- Station Features
- 4.2 Station Feature Descriptions
- Add-On Modules
- 32 AOM
- 64 Button Module
- Appointment Reminder
- Automatic Hold
- Automatic Privacy
- Background Music
- Busy Station Callback
- Busy Station Indications (BLF)
- Call Forwarding
- Call Log
- Call Pickup
- Direct Station Selection (DSS)
- Do Not Disturb (Programmable)
- Door Lock Release
- Exclusive Hold
- Group Listening
- Headset Operation
- Hearing Aid Compatible
- Line Queuing with Callback
- Line Skipping
- Loud Ringing Interface
- Manual Signalling
- Message Waiting Light / Indication
- Mute Microphone / Handset
- Off-Hook Ringing
- Off-Hook Voice Announce (Standard)
- Off-Hook Voice Announce (Executive)
- One Time Do Not Disturb
- One Touch Dialing Keys
- On-Hook Dialing
- Privacy Release
- Programmable Keys
- Programmed Station Messages
- Protection From Barge-In
- Pullout Directory Tray
- Pulse to Tone Switchover
- Redial
- Remote Hold
- Ring Modes
- Ringing Preference
- Speakerphone
- Station Lock
- Tri-Colored Lights
- Volume Settings
- Wall-Mountable Keysets
- Display Features
- 4.3 Display Feature Descriptions
- Account Code Display
- Call Duration Timer
- Call for Group Identification
- Call Processing Information
- Caller ID/ANI Information
- Calling Party Name
- Calling Party Number
- Conference Information
- Date and Time Display
- Dial by Name
- Dialed Number
- Enhanced Station Programming
- Identification of Recalls
- Identification of Transfers
- Message Waiting Caller Number
- Outside Line Identification
- Override Identification
- Programmed Message Display
- Soft Keys
- Stopwatch Timer
- Text Messaging
- UCD Supervisor Displays
- Sample Displays
- Sample Caller ID Displays
- Sample UCD Displays
- 4.4 Sample SMDR Printout (Without Caller ID)
- 4.5 Sample SMDR Printout (With Caller ID and Call Cost)
- 4.6 Sample UCD Report
- 4.7 UCD Call Statistics Overview
- 4.8 UCD Agent Statistics Overview
- 4.9 Sample Traffic Report
- 4.10 Traffic Report Overview
- 4.11 Sample Alarm Report
- Part 5. General User Information

CONTENTS
4.1.20
SYSTEM MAINTENANCE ALARMS
The 400si continuosly performs internal system diagnostics. When either a major
or minor fault is detected the system can ring stations with an ALARM KEY as-
signed. The keyset display shows information that includes the description, loca-
tion and date and time stamp for each alarm.
A log of 100 alarms are stored in a buffer and can be reviewed at a display keyset
or sent to a printer (see sample Alarm Report in section 4.11 of this document). In
addition to the keyset displays LEDs, the front of the DCCU card will light to indi-
cate a major or minor alarm.
SYSTEM DIRECTORY
Each station, station group and outside line can have an 11 character directory
name. This name will appear on keyset displays to provide additional information
about lines and stations.
TENANT SERVICE (2)
There are several programs that allow the DCS 400si to be installed in tenant
applications. These features allow a technician to split the system in two with each
tenant having individual control over operator groups, page zones, ring modes
(manual or automatic), DISA and customer level programming. Each tenant is sepa-
rate. No intercom calling between tenants is permitted.
TOLL RESTRICTION
There are 500 allow and 500 deny entries of 11 digits each. Each of these entries
can apply to dialing classes B, C, D, E, F and G. Expensive 976, 1-900, 411 and
operator-assisted calls, as well as specific area and office codes, can be allowed or
denied on a per-class basis. Class A stations have no dialing restrictions and Class
H stations cannot make outside calls.
Any outside line may be programmed to follow station toll restriction or follow the
toll restriction class assigned to it. Each station and trunk can have a day dialing
class and a night dialing class.
SPECIAL CODE TABLE
A Special Code Table of ten entries (four digits each) allows use of telephone
company features such as CID blocking (✱67) or call waiting disable (✱70) without
interference to toll restriction or LCR. The Special Code table allows use of these
custom calling features on a per call basis.
TOLL RESTRICTION OVERRIDE
Program options allow system speed dial numbers to follow or bypass a station’s
toll restriction class. In addition, users may make calls from a toll restricted station
by using the walking class of service or authorization code feature.