Installation manual

<FIGURE 6-4> MDF CONNECTIONS AOM TO 8DLI CARD
If an AOM is to operate as a stand-alone unit, there is nothing else required other
than assigning keys. When an AOM is to be used with a station, it must be
assigned in MMC 209. Add-on modules can be assigned to any keyset: a
maximum of two AOMs per keyset is allowed. Assign keys in MMC 722.
DCS Compact II INSTALLATION MANUAL Chapter 6. Connecting Station Equipment
6 - 5
CONNECT TO ANY DLI CIRCUIT ON
ANY 8DLI CARD
ADD-ON MODULE
ONE PAIR
T W I S T E D
S H E A T H E D
STATION CABLE
24 OR 26 A W G
25 PAIR CABLE WITH FEMALE CONNECTOR TO BASIC P2
25 PAIR CABLE WITH FEMALE CONNECTOR TO EXPANSION P5
SLOT NO.
PIN NO. 8 DLI 6 DLI
2 5 , 5 0 STN 1 STN 1
2 4 , 4 9 STN 2 STN 2
23,48 STN 3 STN 3
22,47 STN 4 STN 4
2 1 , 4 6 STN 5 STN 5
20,45 STN 6 STN 6
19,44 STN 7 N.C
1 8 , 4 3 STN 8 N.C
17,42 STN 9 STN 1
16,41 STN 10 STN 2
15,40 STN 11 STN 3
14,39 STN 12 STN 4
13,38 STN 13 STN 5
12,37 STN 14 STN 6
11,36 STN 15 N.C
10,35 STN 16 N . C
9,34 STN 17 STN 1
8,33 STN 18 STN 2
7,32 STN 19 STN 3
6,31 STN 20 STN 4
5,30 STN 21 STN 5
4,29 Bn,W 6 STN 22
3,28 Gn,W 7 STN 23
2,27 O,W 8 STN 24
S
L
O
T
4
S
L
O
T
5
S
L
O
T
6
SLOT NO.
PIN NO. COLOUR CIRCUIT 8 DLI
25,50 S,Pu 1 STN 1
24,49 Bn,Pu 2 STN 2
23,48 Gn,Pu 3 STN 3
22,47 O,Pu 4 STN 4
21,46 B,Pu 5 STN 5
20,45 S,Y 6 STN 6
19,44 Bn,Y 7 STN 7
18,43 Gn,Y 8 STN 8
17,42 O,Y 1 STN 9
16,41 B,Y 2 STN 10
15,40 S,Bk 3 STN 11
14,39 Bn,Bk 4 STN 12
13,38 Gn,Bk 5 STN 13
12,37 O,Bk 6 STN 14
11,36 B,Bk 7 STN 15
10,35 S,R 8 STN 16
9,34 B n , R 1 STN 17
8,33 G n , R 2 STN 18
7,32 O,R 3 STN 19
6,31 B , R 4 STN 20
5,30 S,W 5 STN 21
4,29 Bn,W 6 STN 22
3,28 Gn,W 7 STN 23
2,27 O,W 8 STN 24
S L O T
1
S L O T
2
S L O T
3