Installation manual

6.5 Door Phone and Door Lock Release
Using one pair twisted #24 AWG or #26 AWG jumper wire, cross-connect each
DPIM to the DLI port of your choice (See Figures 6–7 and 6–8). Next, connect
the DPIM to the door phone using two pair twisted #24 AWG or #26 AWG jumper
wire.
<FIGURE 6-7> MDF CONNECTIONS DOOR PHONE TO BASIC KSU
DCS Compact II INSTALLATION MANUAL Chapter 6. Connecting Station Equipment
6 - 8
CONNECT TO ANY DLI CIRCUIT
ONE PAIR TWISTED
SHEATHED STATION
C A B L E 24 OR 26
A W G
TO CUSTOMER-PROVIDED
DOOR LOCK RELEASE
DOOR PHONE
INTERFACE
MODULE
(DPIM)
TWO PAIR
M O D U L A R
C A B L E
THREE PAIR
MODULAR CABLE
DOOR PHONE
BLUE
6
W H I T E
1
25 PAIR CABLE WITH FEMALE CONNECTOR TO BASIC P1
PIN C O L O U R C I R C U I T F U N C T I O N
25 S l a t e / p u r p l e
1
D L I TIP
50 P u r p l e / s l a t e D L I R I N G
2 4 B r o w n / p u r p l e
2
D L I TIP
4 9 P u r p l e / b r o w n D L I R I N G
2 3 G r e e n / p u r p l e
3
D L I T I P
4 8 P u r p l e / g r e e n D LI R I N G
2 2 O r a n g e / p u r p l e
4
D L I TIP
4 7 P u r p l e / o r a n g e D L I R I N G
21 B l u e / p u r p l e
5
D L I T I P
46 P u r p l e / b l u e D LI R I N G
20 S l a t e / y e l l o w
6
D L I T I P
45 Y e l l o w / s l a t e D L I R I N G
19 B r o w n / y e l l o w
7
D L I T I P
4 4 Y e l l o w / b r o w n D L I R I N G
1 8 G r e e n / y e l l o w
8
D L I T I P
4 3 Y e l l o w / g r e e n D L I R I N G
123456
DPIM connector
No Door Box Door Lock
1 X Normal-Open
2 L2 X
3 L1 X
4 P+(+12V) X
5 P- (GND) X
6 X Common