Installation manual

One zone control relays is provided by default. If installed, the MISC card
provides three additional zone control relays (See Figure 7–3). These paging
contact pairs are for control of low voltage circuits or amplifier output. The
contacts are rated at 24 VDC-1 amp.
<FIGURE 7-3> MDF CONNECTIONS PAGE AMPLIFIER TO KSU
WARNING
Do not attempt to connect commercial AC power to these contacts.
DCS Compact II INSTALLATION MANUAL Chapter 7. Connecting Optional Equipment
7 - 3
NOTE: THE TACT RELAYS REQUIRE A
MISC CARD
25 PAIR CABLE WITH FEMALE CONNECTOR TO KSU P1
CUSTOMER-PROVIDED
PAGING AMPLIFIER
ZONE 5
ZONE 6
ZONE 7
ZONE 8
I N
O U T
PIN C O L O U R C I R C U I T F U N C T I O N
1 1 B l u e / b l a c k 1 OPEN A
3 6 B l a c k / b l u e OPEN B
1 0 S l a t e / r e d BGM 1A
35 R e d / s l a t e BGM 1B
9 B r o w n / r e d BGM 2A
3 4 R e d / b r o w n BGM 2B
8 G r e e n / r e d 1 PAGE 1A
33 R e d / g r e e n PAGE 1B
7 O r a n g e / r e d PAGE 2A
32 R e d / o r a n g e PAGE 2B
5 S l a t e / w h i t e 2 TACT 1A
3 0 W h i t e / s l a t e TACT 1B
4 B r o w n / w h i t e 3 TACT 2A
2 9 W h i t e / b r o w n TACT 2B
3 G r e e n / w h i t e 4 TACT 3A
2 8 W h i t e / g r e e n TACT 3B
2 O r a n g e / w h i t e ALARM 1
2 7 W h i t e / o r a n g e ALARM 2