2.3 Three Cabinet System
In a fully expanded three cabinet system, there are 26 universal card slots(see Figure 1.3).
This allows a maximum of 360 stations or 352 lines when using TEPRI cards.
Without TEPRI cards, the maximum number of lines is 208 and the maximum number
of stations is 360. The third cabinet is also controlled by a Local Control Processor
(LCP/LCP2) in a similar manner to the LCP/LCP2 in the second cabinet and connects
to the second cabinets LCP/LCP2 via a 25 pair cable. This processor resides in a
dedicated slot 10 and therefore does not deplete the number of universal card slots.
In addition, the MCP card must be equipped with an ESM daughter board and an
IPM daughter board. Only a LAN daughter board may optionally occupy the
remaining daughter board position on the MCP card. All other types of daughter
board must be installed on the SCP/SCP2 card or LCP/LCP2 card.
Figure 1.4 OfficeServ 500 Three Cabinet System