User Manual (Tech Manual)

9
GAS MODEL
TROUBLE SHOOTING
WARNING
To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before
servicing, unless testing requires power.
Radiant Sensor(10RS)
Resistance value < 1 Ω
If resistance is innite, replace Radiant sensor
Igniter(101D)
Resistance value 40~400 Ω
If resistance is innite, replace Igniter
Gas Valve(25M01A)
Valve 1-2 : Resistance value 1.2K Ω
Valve 1-3 : Resistance value 0.5K Ω
Valve 4-5 : Resistance value 1.2K Ω
If resistance is innity, replace Valve
Thermostat (60T21 Hi-Limit)230F-50F
Resistance value < 1 Ω
If resistance is innity, replace Thermostat
Technical_information-03044A-03_EN.indd 9 2012-04-26 �� 12:04:03