8. Operation and Functions
8-1. How to Use Control Panel (continued)
Button Item Display Description
ⓐⓑⓒ
Service Mode
(Error Display)
88 LED
How to Start : In lock mode, press 5 times, while pushing & at once
and & 5sec hold
How to Proceed : operating state values (ex : error codes) are displayed
※ Error display is skipped if no error.
How to End : Press “Control Lock” button 1 time or No input for 20min.
see next page for codes list
If more than one error occurs, they are multiple displayed
ⓐⓑⓗ
Forced Defrosting
-
How to Start : In lock mode, press 5 times, while pushing & at once
and & 5sec hold
How to Proceed : How to Proceed : Heater is on regardless of F/R/IM Defrost Sensor
for first 30sec.
How to End : Same as normal defrosting or Power Rest
ⓑⓒⓖ
Changing Sensor ON/OFF
Temp (for Service)
88 LED
How to Start : In lock mode, press 5 times, while pushing & at once
and & 5sec hold
How to Proceed :
How to End : No input for 10sec
If the refrigerator is disconnected from initial power on before 5 days
after setting change, the value is initialized.
Freezer Refrigerator
Default Value Display F 88 LED “00” R 88 LED “00”
Value “01” = 0.13ºF (0.072℃) 0.18ºF (0.1℃)
Range of Value Change “00 ±30”
= Range of Temp Change 0±3.9ºF (0±2.16℃) 0±5.4ºF (0±3℃)
Control Button to be Warmer
Control Button to be Colder