User Manual

29
/ 78
!
WARNING
To avoid risk of electrical shock that can cause death or severe personal injury,
disconnect unit from power before servicing unless tests require power.
8. Operation and Functions
8-3. Compressor, Fan & Damper
Output
Comp C FAN F FAN R FAN
Icemaker
Room FAN
Pantry
Damper
INPUT
Sensor Target
Temp
Freezer
On/Off On/Off On/Off - - -
Refrigerator
- - - On/Off - -
Pantry Drawer
- - - - Open/Close
Ice
Harvest Condition
& Step Valve Location
- - - - On/Off -
F
Door Open - - - - - -
R
Door Open - - - - - -
Defrosting
Mode Off Off Off Off Off Close
Showroom Mode
(Demo Mode)
Off Off
On only
F Door Open
On only
R Door Open
On only
R Door Open
Open
F
Accela Chill
On/Off
(Coldest Temp
for setting time)
On/Off
(Coldest Temp
for setting time)
On/Off
(Coldest Temp
for setting time)
- - -
R
Accela Chill - - -
On/Off
(Coldest Temp
for setting time)
- Open/Close
Accela
Ice
On
for setting time
(only
ice making
condition)
- - -
On
for setting time
(only
ice making
condition)
-
8-5. Forced Defrost Mode
The defrost mode starts with compressor work time, defrost sensor temp, any error mode, etc.
The defrosting return is done by F and R and Ice Defrost sensor.
Compressor will not restart within 6 min after the refrigerator is disconnected from power supply.
Fan voltage of control mode : Freezer 12V, Refrigerator 12V, Icemaker Room 12V, Condenser 12V
How to Start :
How to Proceed and End: Same as normal defrost mode
8-4. Defrost Mode
Preparation Work INPUT
“Lock” Mode ON
Water
Filter
Ice Maker
+
Smart
Grid
+