R-SENSOR
J2
R042
(31.4㏀)
R044
(2㏀)
R043
(2㏀)
J1
J001 - cut - cut
J002 - - cut cut
Temperature
compensation
0℃ -1.5℃(-2.7 ºF) 0℃ -3℃(-5.4 ºF)
Resistance
R042 R042+R044 R042
R042+R044
+R043
31.4㏀ (31.4+2)㏀ 31.4㏀ (31.4+2+2)㏀
□ R42 : R-SENSOR standard resistance in normal mode (31.4㏀)
□ In case temperature of refrigerator compartment is week or insufficient, take the following action.
J01
J02
8-9 Compensation of Refrigerator Sensor On/Off Temp
• Cut J1 to increase the standard resistance by 2㏀ ⇒ 1.5℃ down (2.7 ºF down)