Specifications
17
1.1.2 CLEARING TOTALS FROM MEMORY
A. ALL MEMORY RAM CLEAR
All programming and totals are cleared.
Use this procedure the first time when the cash register is programmed.
B. RESET ALL TOTALS & COUNTERS
All totals and counters are cleared. ( Consecutive NO. , Z-Counter, Grand total )
This procedure will not effect register programming.
C. RESET GRAND TOTAL ONLY
The Grand total is only cleared.
( 1 ) Unplug the cash register.
( 2 ) Insert lock key marked ‘ C’ into the control lock and turn clockwise, past the position marked
‘ P’ , to the ‘ SERVICE MODE’ ( Master Clear position ). This position is not marked on the
control lock, but the ‘C’ key will travel to this position.
( 3 ) Choose the desired operation from those listed below.
While holding the SPECIFIED key down, plug-in the cash register.
Continue to hold the specified key down until the receipt printer stops printing and the
display shows 0.00.
KEY TYPE
00 ALL MEMORY RAM CLEAR
CHEQUE RESET ALL TOTALS & COUNTERS
CASH/TEND RESET GRAND TOTAL ONLY
* ALL MEMORY RAM CLEAR * * RESET ALL TOTALS & COUNTERS * * RESET GRAND TOTAL ONLY *