Pack Design Guideline (For electrical design)
Portable IT
Power-Tool Medical E-Bike E-Scooter EV/LEV ESS/UPS
4.20V 4.20V 4.10V 4.10V 4.10V 4.10V
4.00V
(4.05V)
4.35V 4.35V 4.20V 4.20V 4.20V 4.20V
4.00V
(4.05V)
CC-CV CC-CV CC-CV CC-CV CC-CV CC-CV CC-CV
0.05C 0.05C 0.025C 0.025C 0.025C 0.025C
0.025C
(Continous)
4.10V 4.10V 4.05V 4.05V 4.05V 4.05V
4.00V
(4.05V)
4.25V 4.25V 4.10V 4.10V 4.10V 4.10V
4.00V
(4.05V)
Min. voltage of
terminate discharging
3.00V 2.50V 3.00V 3.00V 3.00V 3.00V 3.00V
Min. voltage of
over-discharging protection
2.50V 2.00V 2.50V 2.50V 2.50V 2.50V 2.50V
Min. voltage of
terminate discharging
2.50V 2.50V 2.50V 2.50V 2.50V 2.50V 2.50V
Min. voltage of
over-discharging protection
2.30V 2.00V 2.50V 2.50V 2.50V 2.50V 2.50V
2.00V 2.00V 2.00V 2.00V 2.00V 2.00V 2.00V
10/Cell 10/Cell 10/Cell 10/Cell 10/Cell 10/Cell 10/Cell
1.00V 1.00V 1.00V 1.00V 1.00V 1.00V 1.00V
1.0V ~ 3.0V 1.0V ~ 3.0V 1.0V ~ 3.0V 1.0V ~ 3.0V 1.0V ~ 3.0V 1.0V ~ 3.0V 1.0V ~ 3.0V
0.1C ~ 0.5C 0.1C ~ 0.5C 0.1C ~ 0.5C 0.1C ~ 0.5C 0.1C ~ 0.5C 0.1C ~ 0.5C 0.1C ~ 0.5C
BMS Shut Down Voltage**
Max. consumption current of BMS
after shut down
Do not charge***
Pre-charging voltage range****
Current range of Pre-charging
Item
Standard charging voltage (4.20V cell)
Standard charging voltage (4.35V cell)
Charging method
Full-charging cut-off current*
Voltage of Re-charging (4.20V cell)
Voltage of Re-charging (4.35V cell)
LCO
LMO
NCA
NCM
Remark:
* Current of cell which full-charging shall be terminated.
** Voltage condition of BMS which shall be shut down.
*** Under 1.0V voltage, do not charge the cell.
**** Voltage range of cell which shall be charged by Pre-charging.
If a customer’s battery pack cannot meet the requirements above,