Data Sheet
-SAMSUNG SDI Confidential Proprietary –
Spec. No.
ICR18650-26J1
Version No.
1.0
14
▣ Pack Design Guideline (For electrical design)
Portable IT
Power-Tool Medical E-Bike E-Scooter EV/LEV ESS/UPS
4.20V 4.20V 4.10V 4.10V 4.10V 4.10V
4.00V
(4.05V)
4.35V 4.35V 4.20V 4.20V 4.20V 4.20V
4.00V
(4.05V)
CC-CV CC-CV CC-CV CC-CV CC-CV CC-CV CC-CV
0.05C 0.05C 0.025C 0.025C 0.025C 0.025C
0.025C
(Continous)
4.10V 4.10V 4.05V 4.05V 4.05V 4.05V
4.00V
(4.05V)
4.25V 4.25V 4.10V 4.10V 4.10V 4.10V
4.00V
(4.05V)
□ Min. voltage of
terminate discharging
3.00V 2.50V 3.00V 3.00V 3.00V 3.00V 3.00V
□ Min. voltage of
over-discharging protection
2.50V 2.00V 2.50V 2.50V 2.50V 2.50V 2.50V
□ Min. voltage of
terminate discharging
2.50V 2.50V 2.50V 2.50V 2.50V 2.50V 2.50V
□ Min. voltage of
over-discharging protection
2.30V 2.00V 2.50V 2.50V 2.50V 2.50V 2.50V
2.00V 2.00V 2.00V 2.00V 2.00V 2.00V 2.00V
10㎂/Cell 10㎂/Cell 10㎂/Cell 10㎂/Cell 10㎂/Cell 10㎂/Cell 10㎂/Cell
↓ 1.00V ↓ 1.00V ↓ 1.00V ↓ 1.00V ↓ 1.00V ↓ 1.00V ↓ 1.00V
1.0V ~ 3.0V 1.0V ~ 3.0V 1.0V ~ 3.0V 1.0V ~ 3.0V 1.0V ~ 3.0V 1.0V ~ 3.0V 1.0V ~ 3.0V
0.1C ~ 0.5C 0.1C ~ 0.5C 0.1C ~ 0.5C 0.1C ~ 0.5C 0.1C ~ 0.5C 0.1C ~ 0.5C 0.1C ~ 0.5C
□ BMS Shut Down Voltage**
□ Max. consumption current of BMS
after shut down
□ Do not charge***
□ Pre-charging voltage range****
□ Current range of Pre-charging
Item
□ Standard charging voltage (4.20V cell)
□ Standard charging voltage (4.35V cell)
□ Charging method
□ Full-charging cut-off current*
□ Voltage of Re-charging (4.20V cell)
□ Voltage of Re-charging (4.35V cell)
LCO
LMO
NCA
NCM
Remark:
* Current of cell which full-charging shall be terminated.
** Voltage condition of BMS which shall be shut down.
*** Under 1.0V voltage, do not charge the cell.
**** Voltage range of cell which shall be charged by Pre-charging.
If a customer’s battery pack cannot meet the requirements above,