A1. INSTALLATION PROCEDURE
FOR EXHAUST ADAPTOR AND
PROPER DAMPER OPERATION
CHECK
Blower Plate
Damper
Exhaust Adaptor
Retaining Hooks
Back of
Microwave
Oven
1. Slide exhaust adaptor following the instructions
show in diagram.
2. Make sure tape securing damper is removed
and damper pivots easily before mounting
microwave.
You will need to make adjustments to assure
proper alignment with your house exhaust duct
after the microwave is installed.
A2. ADJUST THE EXHAUST ADAPTOR
Open the top cabinet and adjust the exhaust adaptor
to connect to the house duct.
Damper
For Side-toSide
Adjustment,
Slide the Exhaust
Adaptor as Needed
Back of
Microwave
Oven
NOTE: The house duct is needed to connect to the
exhaust adaptor after installation completion.
House Duct
A. OUTSIDE TOP EXHAUST (VERTICAL DUCT)
B. RECIRCULATING (NON-
VENTED DUCTLESS)
B1. ADAPTING MICROWAVE BLOWER
FOR RECIRCULATION
1. Remove and save screw that holds blower plate
to microwave.
2. Lift up the blower plate.
Back of
Microwave Oven
Blower
Retaining
Screws
NOTE: The exhaust adaptor with damper is not
needed for recirculating models. You may want to
save them for possible future use.
3. Remove screw holds blower mortor and carefully
pull out the blower unit. The wires will extend far
enough to allow you to adjust the blower unit.
CAUTION: Do not touch blade of blower for
preventing crack and break. Hold outer case when
the blower pull out or back into.
ME4000R_ME17R7021EB_AA_DE68-04584A-00_EN.indd 12 6/19/2019 4:17:40 PM