Step-by-step installation guide
A. OUTSIDE TOP EXHAUST
(VERTICAL DUCT)
A1. INSTALLATION PROCEDURE FOR
THE EXHAUST ADAPTOR AND
PROPER DAMPER OPERATION
CHECK
The exhaust Adaptor and Damper are
shipped assembled and attached to
the filler-upper.
1. Slide the exhaust adaptor into place as shown
in the diagram above.
2. Make sure the tape securing the damper is
removed and damper pivots easily before you
mount the microwave.
CAUTION: You will need to make adjustments to
assure proper alignment with your house exhaust
duct after the microwave is installed.
A2. ADJUST THE EXHAUST ADAPTOR
After you have installed the microwave, you will
need to open the top cabinet and adjust the exhaust
adaptor so that you can connect it to the house
duct.
For Front-to-Back
Adjustment, Slide the
Exhaust Adaptor as Needed
Blower Plate
Back of
Microwave
Damper
NOTE: You must attach the house duct to the
exhaust adaptor after installation is complete.
House Duct
B. RECIRCULATING (NON-VENTED
DUCTLESS)
B1. ADAPTING THE MICROWAVE
BLOWER FOR RECIRCULATION
2. Lift up the
blower plate.
1. Remove and save the screws
that hold the blower plate to the
microwave.
Back of
Microwave
NOTE: The exhaust adaptor with the damper is not
needed for recirculating models. You may want to
save them for possible future use.