Product specifications

Samsung Electronics 4-14
4-5-5 In case of heating at the cooling mode or cooling at the heating mode
1. Troubleshooting procedure
No
No
No
No
Yes
Yes
Yes
Is the Thermo off?
Is the unit in the defrosting
operation?
Is the compressorin 3 minutes off?
Is much frostin the indoor
heat exchanger?
Does the 4-WAY valve
operate normally?
Is the outdoor air sensor and
outdoor heat exchanger
attachedcorrectly?
Is the 4-WAY valve
connectorconnected
correctly?
Dose thevoltage of
AC220V apply to the
connector of
4-WAY valve coil during
the operation?
Change the setting temperature of remote control
Check Inner wiring of outdoor unit.
After 3 minutes, coolingand heating start automatically
Attach the sensor correctly
Connect the connecter
correctly
Over shortage of the
refrigerant
4-WAY valve coil error
Exchangethe outdoor PCB
Check the resistance value of 4-WAY
valve coil
4-WAY valve main body errorGo to the next page
No
Yes
Yes
Yes
Yes
No
No
No
No
Yes