Installation Guide

English 23
Installation instructions
Supplied parts
The following parts make up the LP conversion kit:
ORIFICES/ORIFICES/ORIFICIOS
LR(WHT)
LF(WHT
)R
F(RED)
RR(YEL)
CENTER
Out(PUR)
In(GRAY)
DG69-00399A
DG96-00686A
(ASSY NOZZLE-KIT)
LR(WHT)
LF(WHT
)R
F(RED)
RR(YEL)
CENTER
Out(WHT)
In(GRAY)
DG69-00399B
DG96-00686B
(ASSY NOZZLE-KIT)
NA30N6555T*/ NA36N6555T* NA30N7755T*/ NA36N7755T*
The all orices’ positions are marked on the provided sheet. The spud in the
pressure regulator is factory-installed for Natural Gas (NG) use. LP conversion
requires spud removal and reinstallation for LP use.
BURNER ORIFICE SIZES AND OUTPUT RATINGS
(LP Gas [Propane] 10 in WCP)
Burner Location BTU Rate Orice size [mm]
RF 11,500 1.04
LF 7,500 0.83
RR 4,000 0.62
LR 7,500 0.83
Center
1
14,500 In: 0.46 / Out: 0.74 (2 pcs)
Center
2
16,500 In: 0.46 / Out: 0.83 (2 pcs)
1
Model NA30N6555T* / NA36N6555T*
2
Model NA30N7755T* / NA36N7755T*
BURNER ORIFICE SIZES AND OUTPUT RATINGS
(Natural Gas 5 in WCP)
Burner Location BTU Rate Orice size [mm]
RF 13,000 1.64
LF 9,500 1.40
RR 5,000 1.01
LR 9,500 1.40
Center
1
19,000 In: 0.70 / Out: 1.30 (2 pcs)
Center
2
22,000 In: 0.85 / Out: 1.36 (2 pcs)
1
Model NA30N6555T* / NA36N6555T*
2
Model NA30N7755T* / NA36N7755T*
NOTE
115
Orice markings:
115 – Denotes 1.15 mm orice size opening.
Install_NA30N6555TG_DG68-01091A-01_EN+MES+CFR.indb 23 5/28/2018 12:50:42 PM