Installation Manuals

10 English
Connecting the powerConnecting the power
Connecting the power
CAUTION
You must check voltage after connecting power cord.
Live 1 - Neutral 120 V
Live 2 - Neutral 120 V
Live 1 - Live 2 208 V / 240 V
Installing a 4-wire power cord
WARNING
The neutral wire of the supply circuit must be connected to the neutral terminal
located in the lower center of the terminal block. The power leads must be
connected to the lower left and the lower right terminals of the terminal block. The
4th grounding lead must be connected to the frame of the range with the ground
plate and the ground screw.
1. Remove the 3 lower terminal screws from the terminal block. Remove the
ground screw and ground plate and retain them.
2. Cut and discard the ground strap. Do not discard any screws.
3. Insert the ground screw into the power cord ground wire terminal ring,
through the ground plate, and into the frame of the range.
4. Insert the 3 terminal screws (removed earlier) through each power cord
terminal ring and into the lower terminals of the terminal block. Be certain that
the center wire (white/neutral) is connected to the center lower position of the
terminal block. Tighten screws securely to the terminal black.
5. Go to Step 5 on page 13 to continue with the installation.
Neutral
terminal
Live 2
Ground wire
(Green)
Ground
screw
Live 1
Ground strap
Ground plate
Black
Black
White
White
Red
Red
CAUTION
You must check voltage after connecting power cord.
Live 1 - Neutral 120 V
Live 2 - Neutral 120 V
Live 1 - Live 2 208 V / 240 V
Install_NE63T8911_AA_DG68-01257A-00_EN.indd 10 2020-03-26  6:27:51