3.  Remove the knockout in the terminal box cover, and then install a UL 
listed or CSA approved 
1
⁄2” strain relief.
E
F
A
B
C
D
A. White wires
B. Black wires
C. UL listed wire connectors
D. Green (or bare) and yellow-green ground wire
E. Home power supply cable
F. UL listed or CSA approved ½” strain relief
4.  Use UL listed wire connectors to connect the black wires (B) together.
5.  Use UL listed wire connectors to connect the white wires (A) 
 together. 
WARNING
Electrical Shock Hazard
Electrically ground blower.
Connect the ground wire to the green and yellow ground wire in the 
terminal box. Failure to do so can result in death or electrical shock.
6.  Connect the green (or bare) ground wire from the home power 
  supply to the yellow-green ground wire (D) in the terminal box using 
  UL listed wire connectors.
7.  Install the terminal box cover.
8.  Reconnect the power.
Complete the Installation 
1.  Replace the bafe lters. See the “Range Hood Care” section.
2.  Check the operation of the range hood fan and lights.     
  See the “Range Hood Use” section.        
  If the range hood does not operate, check to see whether a circuit  
  breaker has tripped or a household fuse has blown.     
  Disconnect the power and check the wiring connections.
NOTE
To get the most efcient use from your new range hood, read the “Range 
Hood Care” section. 
Range Hood Description
The range hood is designed to remove smoke, cooking vapors, and odors 
from the cooktop area. For best results, start the hood before cooking and 
allow it to operate several minutes after cooking to clear all smoke and 
odors from the kitchen. The hood controls are located on the front of the 
hood. 
D
B
C
A
A. Bafe lter
B. Bafe lter handle
C. Blower and light controls
D. LED lamps
 Range Hood Controls 
A B C D E GF H I J
A. Power
B. Low Speed
C. Medium Speed
D. High Speed
E. Boost Speed
F. Timer Display
G. Timer
H. Light
I. Auto  
 Connectivity
J. Bluetooth
A. POWER
 • Press the POWER button and the hood will turn on at default   
  speed (Default Speed : Low).
 • Press again and the hood will return to sleep mode.
B. LOW
 • Press the LOW button and the hood will turn on at Low speed.
C. MED
 • Press the MED button and the hood will turn on at Medium speed. 
D. HIGH
 • Press the HIGH button and the hood will turn on at High speed. 
E. BOOST
 • Press the BOOST button and the hood will increase to Maximum 
  speed for 10 minutes. 
 • After 10 minutes, the hood will slow to High speed.
 • Normal mode 
  High & Boost CFM is the same (390CFM).
 • Power mode 
  High mode is 390 CFM and Boost mode is 600 CFM. 
  See Performance (CFM) Conversion on page 12.
F. Timer Display
 • Shows the timer settings. 