Range Hood Care
Cleaning
IMPORTANT: Clean the hood and grease lters frequently according to
the following instructions. Replace bafe lters before operating the hood.
Exterior surfaces:
• To avoid damage to the exterior surface, do not use steel wool or
soap-lled scouring pads.
• Always wipe dry to avoid water marks.
Cleaning method:
• Liquid detergent soap and water or all-purpose cleanser.
• Wipe with damp soft cloth or nonabrasive sponge, and then rinse with
clean water and wipe dry.
• Do not use cleaning agents containing bleach
Stainless steel bafe lter:
1. Remove the lter by pulling the spring release handle, and then
pulling down the lter.
A
A. Spring release handle
2. Wash the stainless steel bafe lter as needed in a dishwasher or hot
detergent solution.
3. To reinstall the lter, rst make sure the spring release handle is
toward the front. Insert the stainless steel lter into the upper track.
4. Push in the spring release handle.
5. Push up on the stainless steel lter, and then release the handle to
latch it into place.
WARNING
When removing the lter, please hold it with both hands to make sure it
does not fall.
Replacing the LED lamps
The LED lights are replaceable by a service technician only.
See the support contact information in the Warranty section.
Accessories
NOTE
When used in recirculation mode, To Reduce the Risk of Fire and Shock
use only conversion kit Models:
Recirculating kit: NK-AF030FNB/AA
Charcoal lter replacement: NK-AR050FNB/AA
Recirculating kit are not included with the hood.
They must be ordered from your supplier or Samsung service center.
Order the needed kit specifying your hood model and width size.
Recirculating kit
If it is not possible to vent cooking fumes and vapors to the outside, the
range hood can be used in the non-vented (recirculating) version, using a
charcoal lter. Recirculation Kit is available from the dealer or an authorized
parts distributor.
A
B
D
G
F
E
H
A
G
B
D
E
F
C
A. Ceiling
B. Vent cover
C. Soft
D. 6” (15.2 cm) vent
E. Range hood
F. Cabinet
G. Wall
H. 17” (43.2 cm) min.
vent cover height
NOTE
12” (30.5 cm) high cabinets without a soft may allow the 6” (15.2 cm)
vent and vent cover to be seen.
To replace charcoal lter:
NOTE
The maximum BTUs if you use carbon lter is 40 000. If you use the hood
with the carbon lters on and it does not decrease the BTUs the engine
can fail or generate an unsafe act.
1. Cover the grille that covers the blower motor with the charcoal lter
so that the slots on the lter correspond to the pins on the sides of
the motor grille.
C
B
A
A. Charcoal lter
B. Pins
C. Blower motor
2. Turn the charcoal lter clockwise to lock it.
3. Repeat steps 1-2 on the other lter.