Installation Guide

6 English
Preparation
Preparation
Cabinet dimensions - Combi. ovens
Combi Ovens Installed in Cabinet
01 Junction Box
02 Allow a minimum of 22” for clearance to adjacent corners, drawers, walls,
etc. when door is open
A
E
B
G
F
H
I
22”
D
C
J
02
01
Cabinet DIMENSION
A 30” (76.2 cm)
B Min. 1
3
/16” (3.0 cm)
C 12” (30.5 cm)
D Min. 28
1
/2”/ Max. 28
5
/8” (Min. 72.4 cm / Max. 72.7 cm)
E Min. 1”/ Max. 1
1
/4” (Min. 2.5 cm / Max. 3.2 cm)
F 42
1
/4” (107.2 cm)
Cabinet DIMENSION
G Min. 23
1
/2” (Min. 59.7 cm)
H Min 30
1
/2" (Min 755 mm)
I Max. 9
1
/2” (Max. 24.1 cm) – Junction Box
J Min.
11
/16” (1.75 cm) - Wooden cabinet thickness
If codes permit and a separate ground wire is used, it is recommended that a
qualied electrical installer determine that the ground path and the wire gauge are
in accordance with local codes.
Check with a qualied electrical installer if you are not sure the oven is properly
grounded.
This oven must be connected to a grounded-metal permanent wiring system.
Be sure that the electrical connection and wire size are adequate and in
conformance with the National Electrical Code, ANSI/NFPA 70-latest edition or CSA
Standards C22.
1-94, Canadian Electrical Code, Part 1 and C22.2 No. O-M91-latest edition, and all
local codes and ordinances.
A copy of the above code standards can be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471
CSA International
8501 East Pleasant Valley Road
Cleveland, OH 44131-5575
Install_NQ70M6650D_DE68-04454A-00_EN.indd 6 1/9/2017 6:13:30 PM