User manual
29
Output module specifications
Internal circuit and wiring diagram
NX-Y16R: No varistor
NX-Y16RV: Varistor
Product name RELAY output module
Catalog number NX-Y16R NX-Y16RV
Number of output points 16 points
Insulation method Photocoupler
Rated load voltage 2A 250V AC, 2A 30V DC
Response time
OFF → ON 10ms or less
ON → OFF 10ms or less
Life time
Mechanical 30 million times
Electric 200 thousand times
External power supply 24V 150mA or less
Surge protection N/A Varistor
Internal current consumption (5V) 120mA or less
Common method 8 points/1COM
Operation indicator LED
External cable connection type
Terminal block connection (M3.5), Detachable
terminal block (20 pins)
Recommended cable size 0.5 to 1.25 mm
2
Capacity 225g 235g
Types (A) Type
250V AC
30V DC
24V DC
Varistor