User manual

30
Wiring diagram
Internal circuit
Same as NX-Y16RV.
N The COM terminal of the connector has a short inside of the unit.
N For wiring method, See "Terminal Block Type Module Wiring" in Chapter 4.
N Use separate commercial cable harness (NX-CBLRY) and Pin Type Ass'y
(CPL8890) for external connection.
Product name RELAY output module
Catalog number NX-Y32RV
Number of output points 32 points
Insulation method Photocoupler
Rated load voltage 1A 250V AC, 1A 30V DC
Response
time
OFF ON 10ms or less
ON OFF 10ms or less
Life time
Mechanical 30 million times
Electric 200 thousand times
External power supply 24V 150mA or less
Surge protection circuit Varistor
Internal current consumption (5V) 180mA or less
Common method 32 points/1COM
Operation indicator LED
External cable connection type Connector (40 pin x 1 EA)
Recommended cable size 0.2 mm
2
Capacity 300g
Types (B) Type
1 2
3 4
5 6
7 8
9 10
11 12
13 14
15 16
17 18
19 20
21 22
23 24
25 26
27 28
29 30
31 32
33 34
35 36
37 38
39 40
Y1Y0
YE
YF
Y10
Y11
Y1E
Y1F
COM
COM
COM
COM
2
4
6
8
A
C
12
14
16
18
1A
1C
3
5
7
9
B
D
13
15
17
19
1B
1D
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
24V DC+
24V DC-
24V DC-
24V DC+
Max.
250V AC
30V DC