Installation Manual

14 English
Installation requirements
Installation requirementsInstallation requirements
Location requirements
Clearances and dimensions
NOTE
For OTR over Gas Stove, please follow local GAS CODE.
BEFORE YOU BEGIN to install this appliance, refer to the following information,
dimensions, and clearances. Do not locate the range where it may be subject
to strong drafts. Provide adequate clearances between the range and adjacent
combustible surfaces. These dimensions must be met for safe use of the range.
The location of the electrical outlet and gas piping may be adjusted to meet the
following dimensions and clearances.
For installation in Canada, a free-standing range is not to be installed closer than
4.7 in (12 cm) from any adjacent surface.
CAUTION
This range has been designed to comply with the maximum allowable wood
cabinet temperature of 194 °F (90 °C). Make sure the wall covering, countertops,
and cabinets around the range can withstand the heat (up to 194 °F [90 °C])
generated by the range. If not, discoloration, delamination, or melting may occur.
0 in
(0 cm)
24 in
(61 cm)
Lower
Cabinet
Depth
4 in*
(10.2 cm)
6 in*
(15.2 cm)
36 in
(91.4 cm)
30 in
(76.2 cm)
18 in
(45.7 cm)
30 in (76.2 cm)
0 in (0 cm)
Clearance Below
Cooking Top and at
Rear and Sides of
Range
13 in (33 cm)
Overhead
Cabinet
Depth
* Side clearance above cooking surface to any objects, i.e., wall
CAUTION
Do not grasp the knob, handle and push when you install.
CAUTION
DO NOT install the oven so that the door is ush with the cabinet.
For OTR over Gas Stove, please follow local GAS CODE.
NX5000M_NX58M6650WS_AA_DG68-00992A-01_EN+MES+CFR.indb 14 2017-08-16  2:38:30