Installation Guide
16  English
Installation requirements
Installation requirements
CAUTION
Do NOT lift or handle the unit by the cooktop frame.
Fig. 1
C1
C2
C3
C4
1. The counter top around the cut-out 
should be at and leveled (See hatched 
area on Fig. 1).
2. Before installing the unit, measure the 
heights of the two cabinet sides (C1
~
C4), 
front and back (See Fig. 1) from the oor 
to the top of the counter.
3. Level the range using the four leveling 
legs so that the height from the oor 
to the underside of the cooktop frame 
is greater than the tallest cabinet 
measurement by at least 
1
/
16
”.
4. Slide the unit into the cabinet (DO NOT 
PUSH THE UNIT HARD). Make sure the 
center of the unit aligns with the center 
of the cabinet cut-out.
5. The metal ange under each side of the 
cooktop MUST be placed over the cabinet 
countertop for proper unit support. The 
cooktop should NOT rest directly on the 
countertop or else it could cause damage 
to the cooktop voiding the warranty. 
Level the unit if needed.
Gas requirements
Provide adequate gas supply
This range is designed to operate at a pressure of 5 in (13 cm) of water column on 
natural gas or 10 in (25 cm) of water column on LP gas (propane or butane).
Make sure you are supplying your range with the type of gas for which it is 
designed. Do not attempt to convert the appliance from the gas specied in this 
manual to a different gas without consulting the gas supplier.
This range is convertible for use on natural or propane gas. If you decide to use 
this range on LP gas, conversion must be made by a qualied LP installer before 
attempting to operate the range.
For proper operation, the pressure of natural gas supplied to the regulator must be 
between 5 in and 13 in (13 cm and 33 cm) of water column. 
For LP gas, the pressure supplied must be between 10 in and 13 in (25 cm and 
33 cm) of water column.
When checking for proper operation of the regulator, the inlet pressure must be at 
least 1 in (2.5 cm) greater than the operating (manifold) pressure as given.
The pressure regulator located at the inlet of the range manifold must remain in 
the supply line regardless of whether natural or LP gas is being used. 
A exible-metal appliance connector used to connect the range to the gas supply 
line should have an I.D. of 0.5 in (1.3 cm) and be 5 ft (152 cm) in length for ease of 
installation. In Canada, exible connectors must be single-wall metal connectors no 
longer than 6 ft (183 cm) in length.
Do not kink or damage the exible metal tubing when moving the range.
Install_NX60T9700_BEST_BETTER_AA_DG68-01243A-00_EN.indd 16 2020-03-26  6:41:23