Quick Guide

English 21
Installation instructions
Step 7. Connect the range to gas supply
Shut off the main gas supply valve before disconnecting the old range and leave
it off until the new hookup has been completed. Don’t forget to relight the pilot on
other gas appliances when you turn the gas back on.
Because hard piping restricts movement of the range, the use of a CSA
International-certied exible metal appliance connector is recommended unless
local codes require a hard-piped connection.
WARNING
If the information in this manual is not followed exactly, a re or explosion may
result, causing death, personal injury, or property damage.
- Do not store or use gasoline or other ammable vapors and liquids in the
vicinity of this or any other appliance.
- WHAT TO DO IF YOU SMELL GAS:
DO NOT light a match, candle, or cigarette.
DO NOT try to light any appliance.
DO NOT touch any electrical switch.
DO NOT use any phone in your building.
Clear the room, building, or area of all occupants.
Immediately call your gas supplier from a neighbor’s phone. Follow the gas
supplier’s instructions.
If you cannot reach your gas supplier, call the re department.
- Installation and service must be performed by a qualied installer, service
agency, or gas supplier.
Step 6. Replacing the access cover
Replace the access cover on the range back. To replace the wire cover, insert
double projections in the pockets located below the opening and tighten the screw.
WARNING
Do not exceed 25 ft-lbs of torque when making gas line connections.
Overtightening may crack the pressure regulator resulting in a gas leak.
Flexible connector hookup
Installer: Inform the consumer of the location of the gas shut-off valve.
Adapter
Flex
Connector
(6-ft max.)
Adapter
Gas Shut-Off Valve
0.5-in or 0.75-in Gas Pipe
Tubing Line
to Oven
Burner
Control Valve
Gas Flow into Range
Pressure
Regulator
Tubing Line
to Cooktop
Control
Manifold
NOTE
If your area requires a rigid pipe hookup,
contact a qualied installer, service agency,
or gas supplier.
NOTE
The gas shut-off valve should be installed
in an accessible location in the gas piping,
external to the appliance, for the purpose
of turning on or shutting off the gas to the
appliance.