Installation requirements
Single Oven Under counter
D
A
F
E
B
G
C
H
01
02
01  See built-in oven installation for 
complete installation instructions. 
See label on top of approved built-in 
oven models.
02  Refer installation Manual of OVEN.
Size
A Min. 3
3
/4” (9.5 cm)
B 4” (10.1 cm)
C Min. 28
1
/2”/ Max. 28
5
/8” (Min. 72.4 cm / Max. 72.7 cm)
D Min. 1”/ Max. 1
1
/4” (Min. 2.5 cm / Max. 3.2 cm)
E Min. 27
1
/4”/ Max. 27
3
/8” (Min. 69.2 cm / Max. 69.5 cm)
F 24” (61 cm)
G Min. 22” (Min 55.9 cm)
H Max. 9
1
/2” (Max. 24.1 cm) – Junction Box
IMPORTANT:
If installing a range hood or microwave hood combination above the cooktop, 
follow the range hood or microwave hood combination installation instructions for 
dimensions and clearance above the cooktop surface.
G
F
A
C
E
E
D
B
Cooktop
Rear Wall
Countertop
Junction box
Minimum distance to 
combustible side wall above 
countertop (both sides)
NZ30A******(30”)
A 28
1
/2” - 28
11
/16” (724 mm - 728 mm)
B
19
9
/16
” - 19
5
/
8
” (497.4 mm - 499.4 mm)
C Min 1
1
/8” (28 mm). Between cutout and the wall behind the cooktop
D Min 1
1
/2” (38 mm). From front edge of cutout and front edge of countertop
E Min 1” (26 mm). Distance nearest left and right side combustible surface 
above cooktop.
F Junction box or outlet 10” (254 mm) maximum from right-hand side of 
cabinet
G Junction box or outlet 15” (381 mm) minimum from bottom of countertop
Induction Install_NZ30A3060UK_DG68-01383A-00_EN+MES+CFR.indb 5Induction Install_NZ30A3060UK_DG68-01383A-00_EN+MES+CFR.indb 5 2021-05-14  2:23:392021-05-14  2:23:39