3-Wire Cable from Power Supply to 3-Wire Cable from Cooktop
IMPORTANT: where local codes permit, 3-wire cable can be use to supply power. 
In those cases connect connect cooktop ground wire to the neutral wire from the 
junction box.
A
B
C
D
E
F
G
H
I
A.  3-wire cable from power 
supply
B.  L1 wires
C.  Ground (G) or bare ground 
wire (from cooktop)
D.  3-wire cable from cooktop
E.  Junction box
F.  N (normally White) wire (from 
power supply)
G.  UL listed wire connector
H.  L2 (normally Red) wires
I.  UL listed or CSA approved 
conduit connector
1.  Disconnect power.
2.  Remove Junction box cover, if present.
3.  Connect the exible cable condult from 
the cooktop to the junction box using 
a UL listed or CSA approved condult 
connector.
4.  Tighten screws on condult connector, if 
present.
5.  Connect the two L2 wires together using 
the UL listed wire connectors.
6.  Connect the two L1 wires together using 
the UL listed wire connectors.
7.  Connect the Ground (G) or bare ground 
wire from the cooktop cable to the 
Ground (G) or bare ground wire (in the 
junction box) using a UL listed wire 
connectors.
8.  Install junction box cover.
9.  Reconnect power.
4-Wire Cable from Power Supply to 3-Wire Cable from Cooktop
IMPORTANT: Use the 4-wire cable from power supply where local codes do not 
permit connecting the frame-ground conductor to the Neutral (N) junction box 
wire.
A
B
C
D
E
G
H
I
F
A.  4-wire cable from power 
supply
B.  L1 wires
C.  Ground (G) or bare ground 
wire (from cooktop)
D.  3-wire cable from cooktop
E.  Junction box
F.  N (normally White) wire (from 
power supply)
G.  UL listed wire connector
H.  L2 (normally Red) wires
I.  UL listed or CSA approved 
conduit connector
1.  Disconnect power.
2.  Remove Junction box cover if present.
3.  Connect the exible cable condult from 
the cooktop to the junction box using 
a UL listed or CSA approved condult 
connector.
4.  Tighten screws on condult connector, if 
present.
5.  Connect the two L2 wires together using 
the UL listed wire connectors.
6.  Connect the two L1 wires together using 
the UL listed wire connectors.
7.  Connect the Ground (G) or bare ground 
wire from the cooktop cable to the 
Ground (G) or bare ground wire (in the 
junction box) using a UL listed wire 
connectors.
8.  Put a UL listed wire connector on the 
end of the Neutral (N) wire.
9.  Install junction box cover.
10. Reconnect power.
NOTE
• Usually L1 is Black, L2 is Red, Ground (G) is Green or bare wire and Neutral (N) is 
White wire.
• Do not connect the bare ground wire to the Neutral (N) wire in the junction box.