Installation guide

OfficeServ 12 Programming Guide/Ed.00 CHAPTER 2. MMC Programming
© SAMSUNG Electronics Co., Ltd. Page 2-119
407 Forced Trunk Release
Provides a positive forced trunk release to a specific trunk or all trunks in the event of
a trunk lock-up.
PROGRAM BUTTONS
!
VOLUME Used to scroll through options
!
KEYPAD Used to enter selections
!
SOFT Move cursor left and right
!
SPEAKER Used to advance next MMC
!
HOLD Used to clear previous entry
!
ANS/RLS Used to select ALL
ACTION
PROCEDURE DISPLAY
1. Press Transfer button and enter 407
Display shows
[701] TRK RELS.
RELEASE?_Y:1,N:0
2. Dial in trunk number(e.g., 704)
OR
[704] TRK RELS.
RELEASE?_Y:1,N:0
Press Volume button selected trunk and press
Right Soft button
OR
Press ANS/RLS button to select all trunks
[ALL] TRK RELS.
RELEASE?_Y:1,N:0
3. Dial 1 for YES or Dial 0 for NO
(Pressing 1 or 0 will return to step 2)
[704] TRK RELS.
RELEASE?_Y:1,N:0
4. Press Transfer button and enter to exit
OR
Press Speaker button to advance next MMC
DEFAULT DATA
NONE
RELATED ITEMS
NONE