Installation guide

CHAPTER 2. MMC Programming OfficeServ 12 Programming Guide/Ed.00
Page 2-142 © SAMSUNG Electronics Co., Ltd.
426 Trunk Gain Control
Allows loss levels to be adjusted on a per trunk basis. There are two adjustments
available in this MMC. ‘TX’ is the transmit level adjustment of the trunk to the
station. ‘RX’ is the receive level adjustment of the station to the trunk. See the Trunk
Gain Setting Tables for level option definitions.
PROGRAM BUTTONS
!
VOLUME Used to scroll through options
!
KEYPAD Used to enter selections
!
SOFT Move cursor left and right
!
SPEAKER Used to advance next MMC
!
ANS/RLS Used to select ALL
ACTION
PROCEDURE DISPLAY
1. Press Transfer button and enter 426
Display shows
[701] TRK GAIN
RX:+0.0 TX:+0.0
2. Enter desired trunk number(e.g., 702)
via the dial keypad
[702] TRK GAIN
RX:+0.0 TX:+0.0
OR
Press Volume button to make selection
Press Right Soft button to move cursor
3. Press Volume button to make selection
Press Right Soft button to move cursor
[702] TRK GAIN
RX:+0.0 TX:+0.0
4. Press Volume button to make selection
Press Right Soft button to move cursor and
[702] TRK GAIN
RX:+0.0 TX:-2.5
return to step 1
5. Press ANS/RLS button to select ALL
[ALL] TRK GAIN
RX:+0.0 TX:+0.0
6. Press Transfer button and enter to exit
OR
Press Speaker button to advance next MMC
DEFAULT DATA
TX : +0.0
RX : +0.0
RELATED ITEMS
NONE