Installation guide

OfficeServ 12 Programming Guide/Ed.00 CHAPTER 2. MMC Programming
© SAMSUNG Electronics Co., Ltd. Page 2-161
ACTION
PROCEDURE DISPLAY
1. Press Transfer button and enter 503
Display shows
[701] ANS.BAK TM
0600 MS
"
2. Dial trunk number(e.g., 704)
OR
[704] ANS.BAK TM
0600 MS
"
Press Volume button to select trunk and press
Right Soft button to move cursor
OR
Press ANS/RLS button to select all trunks
[ALL] ANS.BAK TM
0600 MS
"
_
3. Dial timer number from the list
OR
[704] DTMF DUR.
0100 MS
"
_
Press Volume button to select timer and press
Right Soft button to move cursor
4. Enter new timer value
(must be four digits, e.g., 0200)
[704] DTMF DUR.
0100 MS
"
0200
System returns to step 2
5. Press Transfer button and enter to exit
OR
Press Speaker button to advance next MMC
DEFAULT DATA
Timer Name Value Range
ANS.BAK TM 0600 MSEC 0-2500 MSEC
CLEARING 1000 MSEC 100-9900 MSEC
CO SUPV TM 2500 MSEC 10-2500 MSEC
DTMF DUR. 0100 MSEC 100-9900 MSEC
F-DGT DELY 0600 MSEC 100-9900 MSEC
FLASH TIME 0600 MSEC 20-2500 MSEC
NO RING TM 04 SEC 1-25 SEC
PAUSE TIME 03 SEC 1-25 SEC
PRS DET TM 0000 MSEC 0-2500 MSEC
RNG DET TM 0050 MSEC 10-2500 MSEC
WINK TIME 200 MSEC 100-300 MSEC
MF/DP INT 0800 MSEC 100-9900 MSEC
MFR DLY TIME 00 SEC 0-25 SEC
RELATED ITEMS
NONE