504 Pulse Make/Break Ratio
Allows the ability to change the value of pulses per second and the duration of the
make/break time. This will only affect rotary dial trunks.
0 : Make/Break Ratio(01-99)
1 : Pulse Per Second(10 or 20)
PROGRAM BUTTONS
!
VOLUME Used to scroll through options
!
KEYPAD Used to enter selections
!
SOFT Move cursor left and right
!
SPEAKER Used to advance next MMC
ACTION
PROCEDURE DISPLAY
1. Press Transfer button and enter 504
Display shows
MAKE/BREAK RATIO
33 MAKE
"
2. Dial 0 or 1 for option
OR
PULSE PER SECOND
10 PPS
"
_
Press Volume button for selection and press Right
Soft button to move cursor
3. Dial new value
System returns to step 2
PULSE PER SECOND
10 PPS
"
20
4. Press Transfer button and enter to exit
OR
Press Speaker button to advance next MMC
DEFAULT DATA
MAKE/BREAK : 3 MAKE
PULSES PER SECOND : 10 PPS
RELATED ITEMS
MMC 402 TRUNK DIAL TYPE