Installation guide

CHAPTER 2. MMC Programming OfficeServ 12 Programming Guide/Ed.00
Page 2-276 © SAMSUNG Electronics Co., Ltd.
800 Enable Technician Program
Used to open and close technician-level programming. If programming is not opened
and an attempt is made to access a system MMC, the error message will be
displayed.
A four digit passcode is required to access this MMC. Each character can be digits
0-9. When opened, this MMC enables access to all MMCs.
PROGRAM BUTTONS
!
VOLUME Used to scroll through options
!
KEYPAD Used to enter selections
!
SOFT Move cursor left and right
!
SPEAKER Used to advance next MMC
ACTION
PROCEDURE DISPLAY
1. Press Transfer button and enter 800
Display shows
ENABLE TECH.PROG
PASSCODE:
2. Enter passcode
ENABLE TECH.PROG
PASSCODE:∗∗∗∗
Correct code shows
ENABLE TECH.PROG
DISABLE TENANT:1
Incorrect code shows
ENABLE TECH. PROG
PASSCODE ERROR
3. Enter 1 to enable or 0 to disable
OR
ENABLE TECH.PROG
ENABLE TENANT:1
Press Volume button to select and press RIGHT
Soft button to move tenant number and enter
tenant number(1-2)
4. Press Speaker button to advance MMC entry
level
801:TEC.PASSCODE
SELECT PROG.ID
5. Enter the MMC desired(e.g., 209)
209:AOM MASTER
AOM NOT EXIST