Installation guide

OfficeServ 12 Programming Guide/Ed.00 CHAPTER 2. MMC Programming
© SAMSUNG Electronics Co., Ltd. Page 2-309
When changing any IP address/value, three digits must be input for each(octet) field.
Example) 192.168.1.10 input must be : 192 168 001 010
The first 3 parameters : SYSTEM IP ADDR, SYSTEM GATEWAY, and SYSTEM NET
MASK are stored separate from the main system database, thus will not be defaulted
when MMC811 ‘CLEAR MEMORY’ is performed. Furthermore, any changes to these
parameters will not be applied until the system is reset.
PROGRAM BUTTONS
!
VOLUME Used to scroll through options
!
KEYPAD Used to enter selections
!
SOFT Move cursor left and right
!
SPEAKER Used to advance next MMC
ACTION
PROCEDURE DISPLAY
1. Press Transfer button and enter 830
Display shows the system IP address.
SYSTEM IP ADDR
165.213. 97.185
2. Press Volume button to make selection and
Press Right Soft button to move cursor.
SYSTEM IP ADDR
165.213. 97.185
3. Using the keypad enter three digit IP octet
numbers
SYSTEM IP ADDR
192.168.001.010
IE 192 168 001 010 for 192.168.1.10
Cursor will return to Step 1 upon completion
of IP address entry.
4. Press Volume button to make selection and
Press Right Soft button to move cursor.
SYSTEM GATEWAY
165.213. 97. 1
5. Using the keypad enter three digit IP octet
numbers
SYSTEM GATEWAY
192.168.001.001
I.e., 192 168 001 001 for 192.168.1.1
Cursor will return to Step 5 upon completion
of system gateway entry.
6. Press Volume button to make selection and
press Right Soft button to move cursor.
SYSTEM RESTART
ARE YOU SURE? NO