CHAPTER 2. MMC Programming OfficeServ 12 Programming Guide/Ed.00
Page 2-342 © SAMSUNG Electronics Co., Ltd.
851 Alarm Reporting
This MMC is used to view, store, print or clear system alarms. There are two levels
of faults displayed via alarm code, major alarms and minor alarms. Major alarms
codes are usually service affecting and require a certified technician to determine the
fault. A minor alarm indicates a fault that may or may not be service affecting and
usually does not seriously degrade the systems operating capabilities. The alarm
buffer will hold up to 100 alarms on a first in-first out(FIFO) basis. Alarms will
provide a date and time stamp based on the system time. If applicable the hardware
cabinet, port, and/or slot will be displayed.
ALARM REPORTING OPTIONS(Select one of the options)
No Option Description
0 VIEW ALARM View alarm buffer
1 OVERFLOW CONTROL Determines buffer control when buffer is full. Default is
OVERWRITTEN.
0 OVERWRITTEN :
When buffer is full, the oldest entry in
buffer overwritten.
1 STOP RECORDING : When buffer is full, stop recording
alarms.
3 CLEAR ALARM BUF Clears alarm buffer.
4 PRINT ALARM BUF Prints contents of alarm buffer to the assigned alarm IO port.
PROGRAM BUTTONS
!
VOLUME Used to scroll through system alarms.
!
KEYPAD Used to enter selections
!
SOFT Enter/leave option
!
SPEAKER Used to store data and move to next MMC
!
TRANSFER Enter/exit MMC