852 System Alarm Assignments
This MMC allows the assignment of system alarms to ring and display the alarms on
stations that have the Alarm Key assigned. The System Alarm Key is programmed in
Station Key Assignments(MMC 722). System Alarm key programming is tenant
wide(tenant 1 and 2). Alarms not programmed to report to the System Alarm key will
still be retained in the maintenance alarm buffer for Alarm Reporting(MMC 851).
The alarm buffer will hold up to 100 alarms on a First In-First Out(FIFO) basis.
Pressing the System Alarm key will silence the audible alarm until another alarm is
generated by the system. The specific fault alarm data can be displayed via MMC
851 System Alarm Reporting.
Alarm Notification Off/On(0/1) determines if the alarm provides a visual and audible
notification to the System Alarm key station(s). Pressing the System Alarm key and
the release key will silence the audible alarm only at the station that pressed the
System Alarm key and the release key. See alarm displays table for assignments.
PROGRAM BUTTONS
!
VOLUME Used to scroll through system alarms.
!
KEYPAD Used to enter selections
!
SOFT Enter/leave option
!
SPEAKER Used to store data and move to next MMC
!
TRANSFER Enter/exit MMC
ACTION
PROCEDURE DISPLAY
1. Press Transfer button and enter 852
Display shows
01:MJA01 ACT:OFF
POR Restart
2. Enter desired Alarm Display number(e.g., 61)
OR
61:MNF01 ACT:OFF
Card Out
Press the Volume buttons to select desired
option and press the Right Soft button and to
advance the cursor.
3. To select if the alarm is active press 1 for
YES and 0 for NO.
61:MNF01 ACT:ON
Card Out