Installation guide

OfficeServ 12 Programming Guide/Ed.00 CHAPTER 2. MMC Programming
© SAMSUNG Electronics Co., Ltd. Page 2-351
861 System Options
This MMC is set to system miscellaneous options.
No Option Description
0 AUTO UPDATE TIME Sets enable(1) or disable(0) the system automatically time and
date update form ISDN call connection message. If sets enable,
when system receives ISDN call connection message, system
checks valid data of encapsulated time and date, and update
system time and date device.
1 SYSTEM SPPED BIN Sets max 500(0) or max 950(1) the maximum number of system
speed dial bin. If sets 500 then same in previous system.
If sets 950, can assign system speed dial block is up to 950 bins
and speed dial bin numbers always 3 digits(000 to 999).
Even if station speed dial bin numbers are 3 digits(000 to 049).
PROGRAM BUTTONS
!
VOLUME Used to scroll through system alarms.
!
KEYPAD Used to enter selections
!
SOFT Enter/leave option
!
SPEAKER Used to store data and move to next MMC
!
TRANSFER Enter/exit MMC
ACTION
PROCEDURE DISPLAY
1. Press Transfer button and enter 861
Display shows
AUTO UPDATE TIME
DISABLE
2. Enter the option number
OR
AUTO UPDATE TIME
DISABLE
Press Volume button to make selection and
press Right Soft button to move cursor
3. Enter 1 or 0 for option data select
OR
AUTO UPDATE TIME
ENABLE
Press Volume button to make selection and
press Right Soft button to move cursor
4. Press Transfer button and enter to exit
OR
Press Speaker button to advance next MMC