Ed.
COPYRIGHT This manual is proprietary to SAMSUNG Electronics Co., Ltd. and is protected by copyright. No information contained herein may be copied, translated, transcribed or duplicated for any commercial purposes or disclosed to the third party in any form without the prior written consent of SAMSUNG Electronics Co., Ltd. TRADEMARKS is the trademark of SAMSUNG Electronics Co., Ltd. Product names mentioned in this manual may be trademarks and/or registered trademarks of their respective companies.
OfficeServ 7030 Installation Manual INTRODUCTION Purpose OfficeServ 7030 is the most suitable system for small offices with 10 to 20 subscribers circuit line. This manual describes the prerequisite for the installation of the OfficeServ 7030 system as well as how to install, inspect and operate the system. Document Content and Organization This document consists of 7 chapters and abbreviations as follows: CHAPTER 1.
Error! Use the Home tab to apply 제목 8,표준 제목 1 to the text that you want to appear here. CHAPTER 6. Connecting the Stations and Additional Equipment This chapter describes how to connect various stations and additional equipment (analog/digital phones, door phones, door locks etc.) to the OfficeServ 7030 system. CHAPTER 7.
OfficeServ 7030 Installation Manual Reference OfficeServ 7030 System Description This manual introduces the OfficeServ 7030 and describes the system information (hardware configuration, specification, functions etc.) necessary for this system. OfficeServ 7030 Service Manual This manual provides an overview, specification, hardware circuit configuration and feature of the system.
Error! Use the Home tab to apply 제목 8,표준 제목 1 to the text that you want to appear here. This page is intentionally left blank. IV © SAMSUNG Electronics Co., Ltd.
OfficeServ 7030 Installation Manual SAFETY CONCERNS For product safety and correct operation, the following information must be given to the operator/user and shall be read before the installation and operation. Symbols Caution Indication of a general caution Restriction Indication for prohibiting an action for a product Instruction Indication for commanding a specifically required action © SAMSUNG Electronics Co., Ltd.
Error! Use the Home tab to apply 제목 8,표준 제목 1 to the text that you want to appear here. Warning WARNING Caution for grounding - Do not connect the OfficeServ 7030 system's grounding wire to the building's power conduit. - The power and grounding installation should comply with the local standard; all related works should be conducted according to the local standard. - External grounding is required to prevent bodily injuries or system damages from lightning, static electricity or voltage surge.
OfficeServ 7030 Installation Manual Caution CAUTION Caution for installation Only a trained service staff may install the OfficeServ 7030 system. The equipment is intended to be installed only in a RESTRICTED ACCESS LOCATION. Leakage currents caused by ringing voltage–Grounding installation instructions 1. A supplementary equipment grounding conductor should be installed between the system and the earth in addition to the default equipment grounding conductor provided in the power supply cord. 2.
Error! Use the Home tab to apply 제목 8,표준 제목 1 to the text that you want to appear here. Prohibition of metal accessories Do not wear metal accessories such as rings and watches to prevent electric damages to the system. AC power connection restriction Do not share the AC power of the OfficeServ 7030 system or the AC power of the external UPS with other devices. Checking power-off Check if the cabinet power is turned off when mounting the board.
OfficeServ 7030 Installation Manual TABLE OF CONTENTS INTRODUCTION I Purpose .................................................................................................................................................. I Document Content and Organization..................................................................................................... I Conventions......................................................................................................................................
Error! Use the Home tab to apply 제목 7,제목 7_목차 to the text that you want to appear here. 2.3 2.2.4 Mounting the daughter Boards ............................................................................................. 2-9 2.2.5 Closing/Cabling ................................................................................................................... 2-12 Replacing the Boards...........................................................................................................
OfficeServ 7030 Installation Manual 6.2.6 Connecting Printers ............................................................................................................ 6-16 CHAPTER 7. Starting the System 7.1 7-1 Pre-Check ............................................................................................................................... 7-1 7.1.1 Environment .......................................................................................................................... 7-1 7.
Error! Use the Home tab to apply 제목 7,제목 7_목차 to the text that you want to appear here. Figure 2.15 Tightening screws to install the daughter boards ............................................... 2-11 Figure 2.16 Installing the top cover (1) .................................................................................. 2-12 Figure 2.17 Installing the top cover (2) .................................................................................. 2-12 Figure 2.18 Cabling ...............................
OfficeServ 7030 Installation Manual LIST OF TABLES Table 1.1 Power Condition ..................................................................................................... 1-2 Table 1.2 Package Items ........................................................................................................ 1-3 Table 1.3 Parts located on the left panel of the cabinet .......................................................... 1-4 Table 1.4 Parts located on the top panel of the cabinet ...................
Error! Use the Home tab to apply 제목 7,제목 7_목차 to the text that you want to appear here. This page is intentionally left blank. XIV © SAMSUNG Electronics Co., Ltd.
OfficeServ 7030 Installation Manual CHAPTER 1. Before Installing This chapter describes the checklists (installation site, grounding & power conditions etc.) which should be inspected before installing the OfficeServ 7030 system. This chapter also describes the items included in the OfficeServ 7030 package and the installation procedure. 1.1 Site Information Select a site that satisfies the following safety, temperature and humidity conditions: 1.1.
CHAPTER 1. Error! Use the Home tab to apply 제목 1,장 제목 1 to the text that you want to appear here. 1.2 Grounding Conditions The following measures should be taken when grounding the OfficeServ 7030 system: y The grounding wire of the OfficeServ 7030 system should be grounded to the earth using a proper material. y The flow electric current between the power outlet’s grounding wire and the system’s metal surface should be satisfactory.
OfficeServ 7030 Installation Manual 1.4 Checking the Package The list of the items included in the OfficeServ 7030 package is as follows: Table 1.
CHAPTER 1. Error! Use the Home tab to apply 제목 1,장 제목 1 to the text that you want to appear here. 1.5 Cabinet Configuration The cabinet of the OfficeServ 7030 system has three slots to install the boards. Figure 1.1 Left Side View of the OfficeServ 7030 Cabinet The descriptions of each part located on the left of the cabinet are listed in the table below. Table 1.3 Parts located on the left panel of the cabinet Part 1-4 Function Power Switch Turns the power of the OfficeServ 7030 system on/off.
OfficeServ 7030 Installation Manual Figure 1.2 Top Side View of the OfficeServ 7030 Cabinet The descriptions of each part located on the top of the cabinet are listed in the table below. Table 1.
CHAPTER 1. Error! Use the Home tab to apply 제목 1,장 제목 1 to the text that you want to appear here. Figure 1.3 Right Side View of the OfficeServ 7030 Cabinet The descriptions of each part located on the right of the cabinet are listed in the table below. Table 1.5 Parts located on the right panel of the cabinet Part Function C.O 1-4 Trunk ports. LAN LAN port. MISC Ports that connect external audio devices, paging device, loud bell, common bell, or door bell.
OfficeServ 7030 Installation Manual CHAPTER 2. Mounting and Replacing the Boards This chapter describes how to mount/replace various boards to/from the OfficeServ 7030 system. 2.1 Connecting the Grounding Wire This section describes how to open the cabinet and connect an external grounding wire to the OfficeServ 7030 system 2.1.1 Opening 1) Hold the cable duct cover and push upward as shown in the following picture. Figure 2.1 Removing the cable duct cover (1) © SAMSUNG Electronics Co., Ltd.
CHAPTER 2. Error! Use the Home tab to apply 제목 1,장 제목 1 to the text that you want to appear here. 2) Push aside the cable duct cover from the main unit. Figure 2.2 Removing the cable duct cover (2) The following figure illustrates the separated cable duct cover. Figure 2.3 Removing the cable duct cover (3) 3) Remove the two screws. Figure 2.4 Removing the screws 2-2 © SAMSUNG Electronics Co., Ltd.
OfficeServ 7030 Installation Manual 4) Push and lift the top cover to open the case. Figure 2.5 Removing the top cover © SAMSUNG Electronics Co., Ltd.
CHAPTER 2. Error! Use the Home tab to apply 제목 1,장 제목 1 to the text that you want to appear here. 2.1.2 Grounding External Grounding External grounding is required to prevent bodily injuries or system damages from lightning, static electricity or voltage surge. The OfficeServ 7030 system should be grounded with an 18AWG or higher electric wire, or an electric wire with a cross-sectional area of 0.8mm2. The nominal thread diameter of the screw should be at least 3.
OfficeServ 7030 Installation Manual 2.2 Mounting the Boards This section describes how to set the base board switches and mount the optional boards. 2.2.1 Removing Dummy Parts Depending on daughter boards, remove the cabinet's dummy parts with a nipper. Figure 2.7 Removing the dummy parts 2.2.2 Setting Switches The base board and EPM board that are equipped with switches relative to the user requirements, system configuration and/or daughter boards are as follows: Table 2.
CHAPTER 2. Error! Use the Home tab to apply 제목 1,장 제목 1 to the text that you want to appear here. Setting switches on base board The base board is equipped with switches relative to the user requirements and system configuration. To set the switches and mount the boards, proceed as follows: Set the base board's S1 switch from SW5 to SW8 to Off. SW1 to SW4 are set depending on the user’s purpose. S1 OFF ON Figure 2.8 Setting the Base Board Switches Table 2.
OfficeServ 7030 Installation Manual 2.2.3 Mounting Optional Boards When mounting the optional board, align the base board connectors to the optional board (EPM or modem) connectors, and press the optional board firmly downward with two hands 1) Mount the modem board to the base board's P7 and P8 connectors. Figure 2.9 Mounting a Modem Board on the Base Board MODEM 2) Mount the EPM board to the base board's P2 connector. EPM Figure 2.
CHAPTER 2. Error! Use the Home tab to apply 제목 1,장 제목 1 to the text that you want to appear here. 3) Set SW1 to SW2 following the user’s purpose. Tighten the screw. Tighten the screws which fit within the grooves of the EPM boards. S1 ON OFF Figure 2.11 Setting Switches on the EPM Board Table 2.3 EPM daughter board switches Switch S1 Description SW1 - ON: Master cabinet - Off: Slave cabinet. SW2 - ON: Standalone - Off: Master and slave 2-8 © SAMSUNG Electronics Co., Ltd.
OfficeServ 7030 Installation Manual 2.2.4 Mounting the daughter Boards The following daughter boards can be mounted on the slots according to the OfficeServ 7030 configuration. Table 2.4 Mountable Boards Part Slot Mountable Board Trunk Part Slot 4 4TM, 2BM Subscriber Part Slot 2 and Slot 3 4DM, 2DM, 4SM, 4LM slot 3 slot 2 slot 4 Figure 2.12 Location of the Base Board Slots The 4TM Module board does not support the Dial Pulse dialing, but it supports the DTMF dialing.
CHAPTER 2. Error! Use the Home tab to apply 제목 1,장 제목 1 to the text that you want to appear here. 1) 2BM or 4TM can be mounted to the base board's P3 connector. Figure 2.13 Mounting 2BM/4TM on the Base Board 2) 2DM, 4DM, 4SM or 4LM can be mounted to the base board's P1 and P4 connector. Figure 2.14 Mounting 2DM/4DM/4SM/4LM on the Base Board 2-10 © SAMSUNG Electronics Co., Ltd.
OfficeServ 7030 Installation Manual 3) Tighten the screws which fit within the grooves of the daughter boards. Figure 2.15 Tightening screws to install the daughter boards © SAMSUNG Electronics Co., Ltd.
CHAPTER 2. Error! Use the Home tab to apply 제목 1,장 제목 1 to the text that you want to appear here. 2.2.5 Closing/Cabling 1) Push and align the top cover to close the case. Figure 2.16 2) Tighten two screws to install the top cover. Figure 2.17 3) Installing the top cover (1) Installing the top cover (2) Fasten the cables to the cabinet with a cable tie. Figure 2.18 Cabling 2-12 © SAMSUNG Electronics Co., Ltd.
OfficeServ 7030 Installation Manual 4) Align and install the cable duct cover as follows. Figure 2.19 5) Installing the duct cover (1) Hold the cable duct cover and push downward as shown in the following picture. Figure 2.20 © SAMSUNG Electronics Co., Ltd.
CHAPTER 2. Error! Use the Home tab to apply 제목 1,장 제목 1 to the text that you want to appear here. 2.3 Replacing the Boards If the OfficeServ 7030 system fails to operate normally due to an error on the power supply board, base board or daughter board, replace the board with a new one. Removing the Cables Before replacing a daughter board, remove all cables connected to the board.
OfficeServ 7030 Installation Manual 3) Remove the screw and extract the board carefully. Figure 2.22 Removing the boards 4) Align the new board to the connector of the slot, and press the daughter boards firmly downward with two hands. Tighten the screw. Figure 2.23 Replacing the daughter boards 5) Close the cabinet. Refer to section ‘2.2.5 Closing/Cabling’. © SAMSUNG Electronics Co., Ltd.
CHAPTER 2. Error! Use the Home tab to apply 제목 1,장 제목 1 to the text that you want to appear here. This page is intentionally left blank. 2-16 © SAMSUNG Electronics Co., Ltd.
OfficeServ 7030 Installation Manual CHAPTER 3. Installing the System This chapter describes how to install an OfficeServ 7030 on the wall, if necessary, depending on the installation environment. 3.1 Installing on a Wall This section describes how to install the OfficeServ 7030 cabinet on a wall. 3.1.1 Required Tools y Mid-sized Phillips screw driver y Electric drill y Hammer y Wall Mount Template y Four plastic Bushings y Four cross-type screws Figure 3.
CHAPTER 3. Error! Use the Home tab to apply 제목 1,장 제목 1 to the text that you want to appear here. 3.1.2 Installing on a Wall To install the OfficeServ 7030 cabinet with a wall mount template, proceed as follows: 1) Drill holes on the marked position of the Wall Mount Template. Drill holes with a minimum of 33 mm depth and approx. 6 mm width to ease the insertion of the plastic bushings. Figure 3.2 Installation on a Wall (1) 2) Fix plastic anchors into the drilled holes with a hammer. Figure 3.
OfficeServ 7030 Installation Manual 4) Align the holes of the OfficeServ 7030 cabinet to the bracket screws, then pull down the cabinet to completely fix on the wall. Figure 3.5 Installation on a Wall (4) 3.2 Connecting the Basic Cabinet to the Expansion Cabinet If the OfficeServ 7030 system consists of a basic cabinet and an expansion cabinet, connect the Base cabinet to the expansion cabinet using the extension cables to allow signal transmissions between the base boards.
CHAPTER 3. Error! Use the Home tab to apply 제목 1,장 제목 1 to the text that you want to appear here. 3) With another extension cable, connect the ‘Link2’ port to the ‘Link2’ port. 4) With the third cable, connect the ‘Link3’ to the ‘Link3. Figure 3.7 Connecting the basic cabinet to the expansion cabinet 3-4 © SAMSUNG Electronics Co., Ltd.
OfficeServ 7030 Installation Manual CHAPTER 4. Connecting thePower This chapter describes how to connect the power to the OfficeServ 7030 system and how to connect the external UPS. 4.1 Connecting the Power 4.1.1 Cautions when Connecting the Power When the input power is normally supplied, the AC current is supplied to the Power Supply Unit (PSU). If the input power is interrupted, the system can be operated using the external UPS.
CHAPTER 4. Error! Use the Home tab to apply 제목 1,장 제목 1 to the text that you want to appear here. 4.1.2 Connecting the Power Single cabinet configuration Use the power cable provided with the OfficeServ 7030 system to connect the input power terminal located on the right panel of the basic cabinet to a grounded outlet. Figure 4.1 Connecting the Power (use of a cabinet) 4-2 © SAMSUNG Electronics Co., Ltd.
OfficeServ 7030 Installation Manual Basic and Expansion Cabinet Configuration Connect each input power cable of the cabinet to a grounded outlet. Figure 4.2 Connecting the Power (using Power cable) © SAMSUNG Electronics Co., Ltd.
CHAPTER 4. Error! Use the Home tab to apply 제목 1,장 제목 1 to the text that you want to appear here. 4.2 Connecting the External UPS An external UPS is required to ensure stable operation of the OfficeServ 7030 system in case of a power failure. The rated capacity of an external UPS is AC 220 200V~240 V per cabinet. The UPS should be connected to each cabinet to guarantee safety. A fuse (125 VAC, 5 A) should be installed between the battery's output terminal and the cabinet's battery connector.
OfficeServ 7030 Installation Manual 4.3 Connecting the Power Fail Transfer The 4TM and the Baseboards support the Power Fail Transfer function. If the AC power fails while the UPS is not connected, connect a power fail transfer circuit by connecting the C.O. lines to the extensions. If a pair of trunk lines (4TM) is connected to Pin1 and Pin2 of the first port in the base board's SLI, the lines will be connected to a phone through Pin 4 and 5 of the 4TM.
CHAPTER 4. Error! Use the Home tab to apply 제목 1,장 제목 1 to the text that you want to appear here. This page is intentionally left blank. 4-6 © SAMSUNG Electronics Co., Ltd.
OfficeServ 7030 Installation Manual CHAPTER 5. Connecting the C.O. Line This chapter describes how to connect the C.O. line to the OfficeServ 7030 system after the installation. 5.1 Line Conditions When connecting the C.O. lines, pay attention to the following criteria: y Use an AWG #24 or AWG #26 cables. y When wiring the cables in humid areas, remove the moisture before wiring. y The cables should be handled carefully to prevent any distortions or damages.
CHAPTER 5. Error! Use the Home tab to apply 제목 1,장 제목 1 to the text that you want to appear here. 5.2 Connecting the C.O. Line This section describes how to connect a common C.O. line (4TM and 2BM) 5.2.1 Cautions When Connecting the C.O. Line When connecting the C.O. line, pay attention to the following criteria to prevent bodily injuries and system damages: y Do not connect the C.O. line in extreme weather conditions such as storm and lightning. y Do not connect the C.O. line in humid areas. 5.2.
OfficeServ 7030 Installation Manual Connecting to the 2BM Board P1, P2 Port (RJ-45) Pin No. 1 2 3 4 5 6 7 8 Function - - TX + RX + RX - TX - - - Figure 5.3 RJ-45 Port (T-Mode only) of the 2BM Board © SAMSUNG Electronics Co., Ltd.
CHAPTER 5. Error! Use the Home tab to apply 제목 1,장 제목 1 to the text that you want to appear here. This page is intentionally left blank. 5-4 © SAMSUNG Electronics Co., Ltd.
OfficeServ 7030 Installation Manual CHAPTER 6. Connecting the Stations and Additional Equipment This chapter describes how to connect various stations and additional equipment (analog/digital phones, door phones, door locks etc.) to the OfficeServ 7030 system. 6.1 Connecting the Stations 6.1.1 Cautions when Connecting the Stations When connecting the stations, pay attention to the following criteria: y Do not connect the stations in extreme weather conditions such as storm and lightning.
CHAPTER 6. Error! Use the Home tab to apply 제목 1,장 제목 1 to the text that you want to appear here. 6.1.2 Connecting Analog Phones Connect an analog phone to the base board's SLT, or to the 4SM board mounted on the OfficeServ 7030 system. Connecting to the Base Board’s SLT Connect an analog phone to the ports of the base board's SLT with a pair of AWG #24 or AWG #26 cables. P1 Port (RJ-45) Pin No. 1 2 3 4 5 6 7 8 Function PFT PFT - SLI SLI - - - TIP RING TIP RING Figure 6.
OfficeServ 7030 Installation Manual Connecting to the 4SM Board Connect an analog phone to the port of the 4SM board with a pair of AWG #24 or AWG #26 cables. P1~ P4-Port (RJ-45) Pin No. 1 2 3 4 5 6 Function - - - SLI SLI - TIP RING 7 8 Figure 6.3 RJ-45 Port of the 4SM Board 6.1.3 Connecting Digital Phones Connect a digital phone to the base board's 4DM. Connecting to the 4DM Board Connect a digital phone to the ports of the base board's 4DM with a pair of AWG #24 or AWG #26 cables.
CHAPTER 6. Error! Use the Home tab to apply 제목 1,장 제목 1 to the text that you want to appear here. 6.1.4 Connecting IP Phones An IP phone is a phone that provides calls through the Ethernet LAN. The interface between a digital phone connected to the OfficeServ 7030 system and an IP phone connected to the LAN is as follows. By default, the base board supports four MGI channels which enables the use of the IP phones.
OfficeServ 7030 Installation Manual 6.1.4.1 Connecting Boards to the Ethernet 4LM/LAN port of the base board can be connected to the Ethernet with an Ethernet cable. y 4LM Board-Line Ports (P1~P4) y Base Board-LAN Port P1~P4 Port (RJ-45) Pin No. 1 2 3 4 5 6 7 8 Function Tx+ Tx- Rx+ - - Rx- - - Figure 6.6 RJ-45 Port of the Ethernet Connection Board 6.1.
CHAPTER 6. Error! Use the Home tab to apply 제목 1,장 제목 1 to the text that you want to appear here. 6.1.6 Connecting a Wireless LAN Access Point The wireless LAN service offered by the OfficeServ 7030 system requires the following equipment: y SMT-R2000: Wireless LAN Access Point (AP) y SMT-W5100: Wireless LAN IP phone Table 6.
OfficeServ 7030 Installation Manual 6.2 Connecting Additional Equipment This section describes how to connect optional equipments (Music on Hold (MOH)/Background Music (BGM) sources, external page devices, common bells etc.) to the OfficeServ 7030 system. 6.2.1 Connecting the MOH/BGM Equipment The OfficeServ 7030 system offers music while on hold. The system provides internal tone/music and external music sources from the C.O. or extension line music sources.
CHAPTER 6. Error! Use the Home tab to apply 제목 1,장 제목 1 to the text that you want to appear here. 6.2.2 Connecting External/Additional Page Equipment Instead of an internal speaker, external broadcasting equipment (amps or speakers) and additional equipment that can broadcast page/ring signals outside the building can be connected to the OfficeServ 7030 system. Connect the external/additional page equipment to the MISC port of the base board mounted on the OfficeServ 7030 system.
OfficeServ 7030 Installation Manual 6.2.4 Connecting Installation Tool The system maintenance software is installed on a PC for programming. The Installation Tool is an application that provides various functions necessary for system maintenance. You can use the Installation Tool when you need to install a new system component or change a system component or modify the database. Below are the specifications required for the PC for programming where the Installation Tool is to be installed. Table 7.
CHAPTER 6. Error! Use the Home tab to apply 제목 1,장 제목 1 to the text that you want to appear here. 6.2.4.1 Connecting a PC for Programming Using a LAN Port You can connect a PC where the Installation Tool is installed to the OfficeServ 7030 system using a LAN port. The Installation Tool allows you to manage the OfficeServ 7030 system remotely. This section describes how to connect a PC for programming to the OfficeServ 7400 system and how to configure the software to use that PC.
OfficeServ 7030 Installation Manual Configuring the network parameters using the MMC 830 program This step configures the network parameters of the OfficeServ 7030 system.. Consult your network administrator for the network parameter values. 1) 2) 3) 4) Set the IP address of the OfficeServ 7030 system. Set the subnet mask of the OfficeServ 7030 system. Set the gateway IP address of the OfficeServ 7030 system. Reset the board. Resetting the Board You have the reset to board to apply the new settings.
CHAPTER 6. Error! Use the Home tab to apply 제목 1,장 제목 1 to the text that you want to appear here. 4) If the Link Type is LAN, enter the IP address of the OfficeServ 7030 system in the [IP Address] field. If the Link Type is MODEM, enter the internal modem number of the OfficeServ 7030 system in the [Telephone] field. 올바른 Modem 접속을 위한 권고 사항 OfficeServ 7030 과 Modem 으로 접속하기 위해서는 반드시 아래에서 예시하는 회사의 외장형 모델중의 한가지를 사용해야 합니다. U.S. Robotics , Hayes , Zoom 6-12 © SAMSUNG Electronics Co., Ltd.
OfficeServ 7030 Installation Manual 6.2.5 Connecting Web Management The OfficeServ 7030 system is equipped with the Web Management web server, and supports the remote access through the network. The system administrator can change the system setting by accessing the Web Management with a browser. This section describes how to access the OfficeServ 7030 system. To use within an in-house network, connect LAN to the LAN port of the base board and try accessing from a client PC.
CHAPTER 6. Error! Use the Home tab to apply 제목 1,장 제목 1 to the text that you want to appear here. Getting access to the Web Management from a client PC 1) Execute your browser. (Internet Explorer 5.5 or higher) 2) Access the Web Management through the LAN IP address. Access address: https://[System LAN IP Address] Figure 6.13 Web Management Initial Screen 3) 6-14 Enter your ID and password on the Web Management initial screen, and click the [OK] button to log in. © SAMSUNG Electronics Co., Ltd.
OfficeServ 7030 Installation Manual 6.2.6 Connecting the SMDR The Station Message Detail Recording (SMDR) computer is used for recording call information, calculating phone bills and/or displaying various analysis data based on the call data provided by the system. The SMDR computer can be connected via the LAN port of the 4LM board or the base board built in the OfficeServ 7030 system. The SMDR system specification is as follows: Table 6.
CHAPTER 6. Error! Use the Home tab to apply 제목 1,장 제목 1 to the text that you want to appear here. 6.2.7 Connecting Printers The OfficeServ 7030 system can be connected to printers. The system can print various call information or event information created by the system in real time whenever an event occurs. To use within the company's LAN network, connect LAN to the LAN port of the base board, and connect a printer to the LAN.
OfficeServ 7030 Installation Manual CHAPTER 7. Starting the System This chapter describes the items to check before starting the OfficeServ 7030 system, as well as the procedure for starting the system and the procedure for testing whether the system is operating normally after startup. 7.1 Pre-Check This section describes the items to check before starting the OfficeServ 7030 system. 7.1.1 Environment y Temperature Check if the room temperature is between 0°C and 40oC.
CHAPTER 7. Error! Use the Home tab to apply 제목 1,장 제목 1 to the text that you want to appear here. 7.1.2 Safety Conditions The building where the OfficeServ 7030 system is installed should have lightning rods and groundings to protect the system from lightning and electric leakage. y Check if the OfficeServ 7030 system is not inclined and is in level position. y Do not place devices that may cause electromagnetic interference near the system. y Place a fire extinguisher near the system.
OfficeServ 7030 Installation Manual 7.3 Numbering Extensions and C.O. Lines Once the OfficeServ 7030 system is booted, the base board verifies the boards mounted on each slot and saves this information as the default configuration of the system. The C.O. line numbers from 701 are sequentially assigned to the C.O. line board mounted on Slot 4 of the basic cabinet, and the subsequent numbers are respectively assigned to the expansion cabinet. This numbering process continues until the C.O.
CHAPTER 7. Error! Use the Home tab to apply 제목 1,장 제목 1 to the text that you want to appear here. 7.4 Checking the System's Operation After starting the OfficeServ 7030 system, check if the system is operating normally. Check if the basic functions of the OfficeServ 7030 system (Station Call, Station Camp-On, C.O. Line Call, C.O. Line Camp-On etc.) are properly executed. 7.4.
OfficeServ 7030 Installation Manual 7.4.3 C.O. Line Call Function Follow the procedure below and check if the external calls are connected normally. 1) 2) 3) 4) 5) Lift the handset of the test phone. Verify the intercom dial tone. Press the C.O. line call code. Verify the C.O. line dial tone. Check if an error tone is activated on the phones that do not support C.O. line calls. Press an external number. Verify the ring back tone. Once the call is connected, check the call status. 7.4.4 C.O.
CHAPTER 7. Error! Use the Home tab to apply 제목 1,장 제목 1 to the text that you want to appear here. This page is intentionally left blank. 7-6 © SAMSUNG Electronics Co., Ltd.
OfficeServ 7030 Installation Manual ABBREVIATION 2 2DM 2 port DLI Module 2BM 2 port BRI Module 4 4DM 4 port DLI Module 4LM 4 port LAN Module 4SM 4 port SLI Module 4TM 4 port Trunk Module AC Alternating Current AFT Automatic Function Test AP Access Point AWG American Wire Gauge BGM Background Music DC Direct Current DLI Digital Line Interface DPIM Door Phone Interface Module DSL Digital Subscriber Line GND Ground IP Internet Protocol A B D G I © SAMSUNG Electronics Co.
Error! Use the Home tab to apply 제목 8,표준 제목 1 to the text that you want to appear here. L LAN Local Area Network LCD Liquid Crystal Display LED Light Emitting Diode MOH Music on Hold M MGI P PCM Pulse Code Modulation PSU Power Supply Unit SLI Single Line Interface SMDR Station Message Detail Recording TEPRI2 T1E1PRI TRK Trunk UTP Unshielded Twisted Pair UPS Uninterruptible Power Supply UTP Unshielded Twisted Pair S T U II © SAMSUNG Electronics Co., Ltd.
OfficeServ 7030 Installation Manual ©2008 Samsung Electronics Co., Ltd. All rights reserved. Information in this manual is proprietary to SAMSUNG Electronics Co., Ltd. No information contained here may be copied, translated, transcribed or duplicated by any form without the prior written consent of SAMSUNG. Information in this manual is subject to change without notice. Unit A1 Brookside Business Park, Greengate, Manchester, M24 1GS U.