Installation manual

CHAPTER 5. Error! Use the Home tab to apply 제목 1, 제목 1 to the text that you want to appear here.
5.2 Connecting the C.O. Line
This section describes how to connect a common C.O. line (4TM and 2BM)
5.2.1 Cautions When Connecting the C.O. Line
When connecting the C.O. line, pay attention to the following criteria to prevent bodily
injuries and system damages:
y Do not connect the C.O. line in extreme weather conditions such as storm and
lightning.
y Do not connect the C.O. line in humid areas.
5.2.2 Connecting Common C.O. Line
Use a pair of AWG #24 (or AWG #26) cable to connect a common C.O. line to the
terminal pin of a terminal box connected to the OfficeServ 7030 system equipped with a
4TM or 2BM board.
Connecting to the 4TM Board
P1 Port
(RJ-45)
Pin No. 1 2 3 4 5 6 7 8
Function PFT
TIP
PFT
RING
- C.O TIP C.O RING - - -
Figure 5.1 P1 (RJ-45) Port of the 4TM Board
P2 ~P4-Port
(RJ-45)
Pin No. 1 2 3 4 5 6 7 8
Function - - - C.O TIP C.O RING - - -
Figure 5.2 P2~P4 (RJ-45) Port of the 4TM Board
5-2