QUESTIONS OR COMMENTS? COUNTRY CALL OR VISIT US ONLINE AT INDIA 1800 3000 8282 - Toll Free 1800 266 8282 - Toll Free 30308282 - Non Toll Free www.samsung.com/in/support This product is RoHS compliant RHF025ETE_IB_E_30611A(5).
RHF025ETE Series RHF035ETE Series RHF050ETE Series RHF080ETE Series RHF100ETE Series ERV(Energy Recovery Ventilator) user manual This manual is made with 100% recycled paper. imagine the possibilities Thank you for purchasing this Samsung product. EN DB98-30611A(5) RHF025ETE_IB_E_30611A(5).
Contents Preparation Safety Precautions ......................................................................................................... 3 Name of Each Part ......................................................................................................... 5 Recommendations for use Cleaning the Dust Filter . ............................................................................................. C leaning the Heat Exchange Element ............................................
Register your product at www.samsung.com/global/register Safety Precautions The following safety precautions are provided to protect the users’ safety and prevent property damage. Make sure to read the followings and use the ventilator properly. Keep this user’s manual together with the installation manual in a handy place so that you can find it whenever you need to see it after reading this manual thoroughly. WARNING This indicates the possibility of serious injury or death.
CAUTION This indicates the possibility of serious injury or damage to environments when operated incorrectly. If the power cable is Do not use the product to Do not clean the product Turn the power off before Be sure to insert the dust Failure to observe the damaged, replace it by the manufacturer or qualified personnel to avoid the risk. repairing the product. Do not let the coming air reach to a pet or plant directly for a long period of time.
Name of Each Part Body 025 Maintenance cover Exhaust Air Heat exchange element Outdoor Air Dust filter Supply Air Electrical component box Return Air Inspection hole 025 Body 035/050/080/100 Return Air Inspection hole (660mm x 600mm) Supply Air Electrical component box Exhaust Air Outdoor Air Dust filter 035/050/080/100 Maintenance cover Heat exchange element 'A' Inspection hole There is an inspection hole for cleaning and maintaining the dust filter and heat exchange
Cleaning the Dust Filter 025 Clean the dust filters at least twice a year. However, the cleaning frequency may vary according to the used period and condition of the ventilator. Clean the dust filters more frequently in dusty place. Make sure that the power supply is disconnected before cleaning the ventilator. Screw Dust filter 1 Remove 3 screws on the maintenance cover. 2 Take off the maintenance cover from the ventilator. 3 Detach the dust filters by pulling them forward.
035/050/080/100 Clean the dust filters at least twice a year. However, the cleaning frequency may vary according to the used period and condition of the ventilator. Clean the dust filters more frequently in dusty place. Make sure that the power supply is disconnected before cleaning the ventilator. 1 Remove 2 screws on the maintenance cover. 2 Take off the maintenance cover from the ventilator. Screw 3 Detach the dust filters by pulling them forward.
Cleaning the Heat Exchange Element 025 Clean the heat exchange element at least twice a year. However, the cleaning frequency may vary according to the used period and condition of the ventilator. Clean the heat exchange element more frequently in dusty place. Make sure that the power supply is disconnected before cleaning the ventilator. Screw Heat exchange element 1 Remove 3 screws on the maintenance cover. 2 Take off the maintenance cover from the ventilator.
035/050/080/100 Clean the heat exchange element at least twice a year. However, the cleaning frequency may vary according to the used period and condition of the ventilator. Clean the heat exchange element more frequently in dusty place. Make sure that the power supply is disconnected before cleaning the ventilator. 1 Remove 2 screws on the maintenance cover. 2 Take off the maintenance cover from the ventilator. Screw 3 Detach the 2 heat exchange elements in order.
Final Checks & User Tips Checking Up the Sub Power Supply The sub power supply is a device to prevent electric leakage due to the over current. Install the sub power supply separately near the ventilator and turn it off when you clean the ventilator or you do not use the ventilator for a long period of time. Turn on the sub power supply which is installed separately. - The sub power supply is not supplied with the ventilator. Purchase the sub power supply individually.
Troubleshooting Problem Explanation/Solution The ventilator does not operate C heck a power failure. Check the sub power supply is on. The air does not come out from the air outlet C heck whether dust filter or heat exchange element is blocked by dust. In case of dust accumulation, it may decrease the efficiency of the ventilator. Clean the dust filter and the heat exchange element frequently. C heck whether the air intake or outlet is blocked by dust. Remove all dust in the air intake.