CLOCK & POWER MANAGEMENT    S3C2440A RISC MICROPROCESSOR 
7-12   
NORMAL Mode 
In Normal mode, all peripherals and the basic blocks including power management block, the CPU core, the bus 
controller, the memory controller, the interrupt controller, DMA, and the external master may operate completely. 
But, the clock to each peripheral, except the basic blocks, can be stopped selectively by software to reduce the 
power consumption. 
IDLE Mode 
In IDLE mode, the clock to the CPU core is stopped except the bus controller, the memory controller, the interrupt 
controller, and the power management block. To exit the IDLE mode, EINT[23:0], or RTC alarm interrupt, or the 
other interrupts should be activated. (EINT is not available until GPIO block is turned on). 
SLOW Mode (Non-PLL Mode) 
Power consumption can be reduced in the SLOW mode by applying a slow clock and excluding the power 
consumption from the PLL. The FCLK is the frequency of divide_by_n of the input clock (XTIpll or EXTCLK) 
without PLL. The divider ratio is determined by SLOW_VAL in the CLKSLOW control register and CLKDIVN 
control register. 
Table 7-3. CLKSLOW and CLKDIVN Register Settings for SLOW Clock example 
SLOW_VAL FCLK  HCLK  PCLK  UCLK 
 1/1 Option 
(HDIVN=0) 
1/2 Option 
(HDIVN=1) 
1/1 Option 
(PDIVN=0) 
1/2 Option 
(PDIVN=1) 
0 0 0  EXTCLK or 
XTIpll / 1 
EXTCLK or 
XTIpll / 1 
EXTCLK or 
XTIpll / 2 
HCLK  HCLK / 2  48 MHz 
0 0 1  EXTCLK or 
XTIpll / 2 
EXTCLK or 
XTIpll / 2 
EXTCLK or 
XTIpll / 4 
HCLK  HCLK / 2  48 MHz 
0 1 0  EXTCLK or 
XTIpll / 4 
EXTCLK or 
XTIpll / 4 
EXTCLK or 
XTIpll / 8 
HCLK  HCLK / 2  48 MHz 
0 1 1  EXTCLK or 
XTIpll / 6 
EXTCLK or 
XTIpll / 6 
EXTCLK or 
XTIpll / 12 
HCLK  HCLK / 2  48 MHz 
1 0 0  EXTCLK or 
XTIpll / 8 
EXTCLK or 
XTIpll / 8 
EXTCLK or 
XTIpll / 16 
HCLK  HCLK / 2  48 MHz 
1 0 1  EXTCLK or 
XTIpll / 10 
EXTCLK or 
XTIpll / 10 
EXTCLK or 
XTIpll / 20 
HCLK  HCLK / 2  48 MHz 
1 1 0  EXTCLK or 
XTIpll / 12 
EXTCLK or 
XTIpll / 12 
EXTCLK or 
XTIpll / 24 
HCLK  HCLK / 2  48 MHz 
1 1 1  EXTCLK or 
XTIpll / 14 
EXTCLK or 
XTIpll / 14 
EXTCLK or 
XTIpll / 28 
HCLK  HCLK / 2  48 MHz 
In SLOW mode, PLL will be turned off to reduce the PLL power consumption. When the PLL is turned off in the 
SLOW mode and the user changes power mode from SLOW mode to NORMAL mode, then the PLL needs clock 
stabilization time (PLL lock time). This PLL stabilization time is automatically inserted by the internal logic with lock 
time count register. The PLL stability time will take 300us after the PLL is turned on. During PLL lock time, the 
FCLK becomes SLOW clock. 