Laptop User Manual
S3C2440A RISC MICROPROCESSOR     I/O PORTS  
  9-27 
EXTINTn(External Interrupt Control Register n) 
The 8 external interrupts can be requested by various signaling methods. The EXTINT register configures the 
signaling method between the level trigger and edge trigger for the external interrupt request, and also configures 
the signal polarity. 
To recognize the level interrupt, the valid logic level on EXTINTn pin must be retained for 40ns at least because of 
the noise filter. 
Register Address R/W  Description  Reset Value 
EXTINT0  0x56000088  R/W  External Interrupt control Register 0  0x000000 
EXTINT1  0x5600008c  R/W  External Interrupt control Register 1  0x000000 
EXTINT2  0x56000090  R/W  External Interrupt control Register 2  0x000000 
EXTINT0 Bit  Description 
EINT7  [30:28]  Setting the signaling method of the EINT7. 
000 = Low level 001 = High level 01x = Falling edge triggered 
10x = Rising edge triggered 11x = Both edge triggered 
EINT6  [26:24]  Setting the signaling method of the EINT6. 
000 = Low level 001 = High level 01x = Falling edge triggered 
10x = Rising edge triggered 11x = Both edge triggered 
EINT5  [22:20]  Setting the signaling method of the EINT5. 
000 = Low level 001 = High level 01x = Falling edge triggered 
10x = Rising edge triggered 11x = Both edge triggered 
EINT4  [18:16]  Setting the signaling method of the EINT4. 
000 = Low level 001 = High level 01x = Falling edge triggered 
10x = Rising edge triggered 11x = Both edge triggered 
EINT3  [14:12]  Setting the signaling method of the EINT3. 
000 = Low level 001 = High level 01x = Falling edge triggered 
10x = Rising edge triggered 11x = Both edge triggered 
EINT2  [10:8]  Setting the signaling method of the EINT2. 
000 = Low level 001 = High level 01x = Falling edge triggered 
10x = Rising edge triggered 11x = Both edge triggered 
EINT1  [6:4]  Setting the signaling method of the EINT1. 
000 = Low level 001 = High level 01x = Falling edge triggered 
10x = Rising edge triggered 11x = Both edge triggered 
EINT0  [2:0]  Setting the signaling method of the EINT0. 
000 = Low level 001 = High level 01x = Falling edge triggered 
10x = Rising edge triggered 11x = Both edge triggered 